C500 AP Air Pot Coffee Brewer
TROUBLE SHOOTING CONTINUED:
POSSIBLE CAUSE | SOLUTION |
13. Defective brew timer | Make sure the timer is receiving 110 to 120 volts at terminals B and A. |
Measure the voltage across terminals 6 and A on the timer when it has | |
| been activated. There should be 110 to 120V going to the dump valve. If |
| not, then the timer is faulty. Replace timer. |
|
|
14. Defective dump valve | If the timer is functioning properly (step 13); next check the dump valve. |
or coil | Measure voltage across the two terminals of the valve coil. You should |
| read 110 to 120 volts. Check also for clogging or lime deposits. Clean |
| lime or clog if present. Replace valve or coil. |
|
|
WIRING DIAGRAM
COMMON STUD
CHASIS GROUND
[ 5 ]