PROGRAM MENUS CONTINUED
Temperature
Energy Save Mode
Temperature (Factory set to 204 °F)
Press to Select. Press < or > to move to desired temperature and then to set. Temperature is programmable from 170ºF to 204ºF in
Energy Save Mode (Factory set to OFF)
Press to Select, < or > ON, OFF or ON 140ºF , to set. When in ON, unit will automatically shut off 4 hours from last brew. When feature is OFF, unit does not have the energy saving mode.
In the ON 140ºF position, temperature goes down to 140ºF. if unit has not brewed in 4 hours. This feature will save energy by maintainig a lower temperature in the tank during periods of
Brew Count Odom
Brew Count Total
Cold Brew Lock
Brew Count Odom.
Press to display total brew cycles. Press ex or Reset
Brew Count Total
Press to Select, Shows total gallons and total brew cycles on the unit. Not resettable.
Cold Brew Lock . . . (Factory set to 5º F)
Press to select, < or > to select desired setting (CBL 5, 15 or OFF), to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set point for the Ready to Brew message, however it will brew at any temperature.
Master Reset
Master Reset
Press to display Are You Sure? Then < for Yes, > for No.
Brewer factory defaults are then reset.
Service Call
Service Call (Phone number Factory set to [800]
Press to display number and change number or < to move place and EX to exit when complete. This number will be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code
Access Code (Factory set to
Press to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit when complete.
Banner Name
Beeper On/Off
Banner Name (Factory set to WILBUR CURTIS)
Press to display letters and change letters or < to move place and EX to exit when complete
This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks disables Banner Name. If programmed, Banner Name is displayed every 5 sec. on and off.
Press to Select, Set gallons brewed to indicate
Beeper On/Off (Factory set to ON)
Press to display ON or OFF. Pressing either < or > toggles between on and off. to set. When ON, this feature allows you to hear a short beep each time a button is pressed.
Model Select
Exit
Model Select
Press to Select. Display TCT G3 .
Exit
Press to select, exits program mode and returns unit to operation. Pressing > returns you to Brew By Volume.
Tank Temperature Check
Turn on brewer at the control panel ON/OFF button. Press and hold 3 button (see illustration, page 2) for 5 seconds. Water Temperature will
be displayed (temperature in heating tank). | 3 |
|