PROGRAM MENUS CONTINUED

Temperature

Energy Save Mode

Temperature (Factory set to 204 °F)

Press to Select. Press < or > to move to desired temperature and then to set. Temperature is programmable from 170ºF to 204ºF in 2-degree increments.

Energy Save Mode (Factory set to OFF)

Press to Select, < or > ON, OFF or ON 140ºF , to set. When in ON, unit will automatically shut off 4 hours from last brew. When feature is OFF, unit does not have the energy saving mode.

In the ON 140ºF position, temperature goes down to 140ºF. if unit has not brewed in 4 hours. This feature will save energy by maintainig a lower temperature in the tank during periods of non-operation.

Brew Count Odom

Brew Count Total

Cold Brew Lock

Brew Count Odom.

Press to display total brew cycles. Press ex or Reset

Brew Count Total

Press to Select, Shows total gallons and total brew cycles on the unit. Not resettable.

Cold Brew Lock . . . (Factory set to 5º F)

Press to select, < or > to select desired setting (CBL 5, 15 or OFF),to set.

The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set point for the Ready to Brew message, however it will brew at any temperature.

Master Reset

Master Reset

Press to display Are You Sure? Then < for Yes, > for No.

Brewer factory defaults are then reset.

Service Call

Service Call (Phone number Factory set to [800] 995-0417)

Press to display number and change number or < to move place and EX to exit when complete. This number will be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.

Access Code

Access Code (Factory set to 1-2-3-4)

Press to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit when complete.

Banner Name

P-Maintenance

Beeper On/Off

Banner Name (Factory set to WILBUR CURTIS)

Press to display letters and change letters or < to move place and EX to exit when complete

This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks disables Banner Name. If programmed, Banner Name is displayed every 5 sec. on and off.

P-Maintenance (Factory set to OFF)

Press to Select, Set gallons brewed to indicate P-Maintenance. Press < or > to adjust from Off to 3000 gallons. Press to exit.

Beeper On/Off (Factory set to ON)

Press to display ON or OFF. Pressing either < or > toggles between on and off. to set. When ON, this feature allows you to hear a short beep each time a button is pressed.

Model Select

Exit

Model Select

Press to Select. Display TCT G3 .

Exit

Press to select, exits program mode and returns unit to operation. Pressing > returns you to Brew By Volume.

Tank Temperature Check

Turn on brewer at the control panel ON/OFF button. Press and hold 3 button (see illustration, page 2) for 5 seconds. Water Temperature will

be displayed (temperature in heating tank).