THE COMFORT PRODUCTS PEOPLE
TROUBLESHOOTING
Continued
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
Ignition failures | 5. | Burner cycles off and glo bar comes on | 5. | A. Check flame sensing probe. Be sure |
|
| immediately, check the following: |
| probe is positioned in the burner |
|
|
|
| flame and glowing cherry red. Check |
|
|
|
| wire and wire connections at probe |
|
|
|
| and ignition control |
|
|
|
| B. If wire and wire connections okay, |
|
|
|
| check for voltage across brown and |
|
|
|
| orange wires at ignition control. If |
|
|
|
| no voltage, replace ignition control |
|
|
|
| C. If voltage present, check wiring and |
|
|
|
| wire connections at valve |
|
|
|
| D. If wire and wire connections okay, |
|
|
|
| replace valve |
|
|
|
|
|
Excessive noise | 1. | Blower out of balance | 1. | Replace blower |
| 2. | Motor hums | 2. | Replace motor |
|
|
|
|
|
Main burner will not cycle off | 1. | Thermostat setting | 1. | Check thermostat |
| 2. | Gas valve stuck open | 2. | Check gas valve. If stuck open, replace. |
|
|
|
| Do not attempt to repair valve! |
|
|
|
|
|
Furnace will not operate | 1. | Wiring connections or shorts | 1. | Check all wiring to assure proper con- |
|
|
|
| nection or detect possible shorts |
www.desatech.com
18 | 201843 |