SAFTY WARNING: Turn off power circuit at the service entrance and lockout panel before wiring the range hood.
BACKDRAFT DAMPER: It is recommended that a backdraft damper be used in all installations. In cold weather installations it is necessary to use a backdraft damper to minimize backflow of cold air into room. A
NOTE: Unit must be vented to outside of the building.
Prepare cabinet for mounting the hood per
electric appliances. Not recommended for use over solid fuel fired appliances.
Attach and secure the transition to the hood with #6x3/8 sheet metal screws and tape all joints prior to installing the hood. Attach hood to cabinet using #10 wood screws. Holes are located in the back panel and top panel of the hood for mounting. Use a minimum of four #10x3/4 wood screws to mount the hood. Longer screws are required if wall board or other nonstructural surfaces are used between the hood and main mounting surface which
holes for additional mounting use appropriate anchors if not engaging the wood structure.
HINT: If you find vibration noise is present because of cabinet structure use additional screws, in holes available, to rigidize mounting.
Connect 120 volt, 60 Hz power through the conduit hole in top of hood, connecting to pigtail in hood junction box, white to white, black to black and connect green ground wire to the power supply ground wire per local codes.
The recommended height from countertop or cooking surface to the bottom edge of the hood is 30 to 36 inches. Hood is recommended for use over domestic gas or
After installing the hood, install the internal blower (see
CAUTION: The hood is of sufficient weight that two installers are recommended to prevent injury or damage to the hood in handling.
Turn the power on at the service entrance and check the operation of the controls.
NOTE: be sure that all dampers are operating properly and are free to open.