NOTE: Wiring harness #10220 is required to complete the installation of dual VEN060I ventilators and must be ordered separately.
Cabinet MountingWhen using two (2) VEN060I ventilators the cabinet mounting must accommodate two discharge transitions. Wiring and discharge holes are shown in FIG 6.
HINT: Transition dimensions may very. Before assembling transitions to hood, fit them into the prepared cabinet opening to be sure the openings are large enough to accommodate the transition. Enlarge the hole if required
Hood PreparationThe hood must be prepared for dual ventilat
discharge hole plates. To remove, break the metal webs holding the plate and remove completely. See FIG 5. Break the metal webs by placing a screwdriver at one corner of the plate and hitting screwdriver sharply with a hammer. After breaking a second web the plate can be flexed to break other webs.
Wear eye protection when using tools.Attach the transition (See DUCTING, pg 1), obtained separately from your local hardware or available through your dealer, and install the hood as described previously in this instruction.
Ventilator InstallationInstall the ventilators as previously described, see FIG 1 and instruction on same page of this document. Connect the
ventilators to the receptacle in the hood junction box using Harness #10220, ordered separately. Dress the wires and
5, using the wire tie supplied with the harness. Follow the remaining instructions for operating checks to complete the installation.
FIG - 5
AIR DISCHARGE | AIR DISCHARGE |
KNOCKOUTS | KNOCKOUTS |
HOOD TOP
HOOD BACK | "A" | TIE |
| ||
|
|