NOTE: ALL SETTINGS CAN BE VIEWED ON THE REMOTE DISPLAY

a)Operating Condition - The protective device will be tripped, and the unit will shut off under these two conditions:

Cooling: (1) Outdoor air temperature is over 109oF (*43oC). (2) Room temperature is below 61oF (16oC).

Heating: (1) Outdoor air temperature is below 23oF (-5oC).

Dry: Room temperature is below 61oF (16oC).

If the air conditioner runs in COOLING or DRY mode with door or window opened for a long time when relative humidity is above 80% condensation may drip down from the outlet.

b) Features of Protector

Restarting the unit at once after operation stops or if changing mode during operation, you need to wait 3 minutes.

Connect to power supply and turn on the unit at once, it may start 20 seconds later.

If the plug is taken out, when you restart the appliance, it will return to the original mode, TIMER ON and TIMER OFF must be set again.

CONDENSATION ELIMINATION SYSTEM

While air conditioning mode, the unit automatically dehu- midifies the air in the room. The water from dehumidifica- tion is stored in a collecting tank and then is immediately “evaporated” and evacuated via the exhaust port.

However, when it is extremely humid, the water in the col- lecting tank may fill up. In this case, the Water Full Indicator Light turns on and the air conditioner switches itself off.

It is then necessary to drain the water through the conden- sate drain hose. For draining instructions, please refer to the “Long Term Storage” instructions under the “Cleaning and Storage” instructions.

Before cleaning the unit, turn it off and unplug it from the outlet. For safety reasons, never wash the air conditioner by hosing it down or wiping it with a dripping wet sponge or cloth.

Exterior surfaces of the unit

Clean the air conditioner by using a damp sponge, and dry it with a clean, soft cloth.

Never use alcohol or any product containing solvents.

Never sprinkle water onto the unit. This may cause an electric shock.

Air filter

The air filter located on the back of the unit, collects dust contained in the air. To keep the dust from clogging the unit, your unit must always be used with its air filter.

The build up of dust reduces the efficiency of the air conditioner. Therefore, the air filter must be cleaned every 100 hours of use, and every two weeks if the unit operates in a dusty atmosphere.

If the filters are obstructed, the air conditioner will be less efficient.

To remove the air filter, place fingers in the notch just under the top of the air filter handle and pull up.

Clean the filter with a vacuum cleaner. If the filter is very dirty, you can wash it in warm water (never use hot or soapy water). Make sure that the air filter is completely dry before putting it back in the unit.

Do not bend the filter.

LONG TERM STORAGE

At the end of the season, or when you do not plan to use the unit for an extended period of time, we recommend

that you take the following steps:

Drain Hose

Drain excess water from the drainpan from the Drain Hose

Run the unit for 3 to 4 hours in fan mode. This will thoroughly dry the inside of the unit.

Disconnect the unit and wrap the power cord and plug around the cord hooks in the back.

Take out the batteries from the remote.

Remove the air hoses and cover the air intake and air outtake holes with the included covers.

Clean the unit and air filter and store it in it’s original packaging, protecting it from dust.

Store the unit in an upright position. Keep it in a cool, dry place and away from sunshine.

Using the unit in wine cellars or in any room with a temperature under 61oF is not recommended.

Blocking of the filter reduces the efficiency of the air and increases its power consumption by up to 6%.

Avoid opening doors frequently.

Each person present in a room provides between 100 Watts and 150 Watts of heat. Consequently, the more people there are in a room, the less effective the unit will be in cooling.

To ensure the optimal efficiency of the unit, we advise you to keep doors and windows closed, and to take into account the surface of the walls and windows exposed to the sun. In this case, in order to optimize the functioning of your air conditioner, we recommend partially closing window coverings.

Cooling Capacity:

12,000 BTU/Hour

Heating Capacity:

11,000 BTU/Hour

Power Input: Cooling

1400Watt/12.5Amps

Heating

1380 Watt/12.3Amps

Energy Efficiency Ratio:

7.80

Coolant:

R-22/500g

Moisture Removal:

2.5 Pints / Hour

 

(60 Pints / Day)

Airflow Volume:

177 CFM (Cubic Feet / Minute)

Noise Level:

49 db

Compressor Type:

Rotary

Operating Temperature Range:

Cooling:

61o - 108oF (16o - 42oC)

Heating: 23o - 90oF (-5o- 32oC)

Voltage/Frequency:

115V/60Hz

Ionization Capacity:

100,000 PCS/CM3

Product Dimension (WxHxD):

 

17.7” (W) x 32.28” (H) x 18.3” (D)

 

45cm(W) x 82cm(H) x 46.5cm(D)

Product Weight:

Net Weight: 82lbs. / 37.3kgs.

1.All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.

2.Check available power supply and resolve any wiring problems before installation and operation of this unit.

3.This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to

reduce the risk of electric shock. This product is equipped with a cord having an equipment grounding conductor and a three prong grounding plug. The plug must be plugged into an appropriate three prong outlet that is properly installed and grounded in accordance with all local codes and ordinances. Do not use plug adapters or extension cords with this unit.

This unit is provided with a Leakage Current Detection and Interruption circuit (LCDI) built into the plug of the power supply cord. This device provides protection to reduce the risk of fire due to arcing faults in the power-supply cord. Each time before using the Room Air Conditioner, follow the "Plug Testing Instructions" given below to ensure that the LCDI circuit is functioning properly.

PLUG TESTING INSTRUCTIONS:

1.PRESS TEST BUTTON. UNIT SHOULD TRIP.

2.FIRMLY PRESS RESET BUTTON FOR USE.

DO NOT USE IF ABOVE TEST FAILS.

The conductors inside this power supply cord are sur- rounded by shields which monitor the leakage current. These shields are not grounded. Periodically examine the cord for any damage. If the shield gets exposed, immedi- ately unplug the power supply cord and do not use the unit. Do not repair a damaged cord. Replace the damaged cord only with a new replacement power supply cord obtained from the manufacturer.

In the event the LCDI Plug of the power supply cord trips by itself, then first examine the cord for any damage. If there is no damage to the cord then press the RESET Button. If the LCDI Plug trips again, then immediately unplug the power supply cord. Replace the damaged cord with a new replacement power supply cord.

To obtain a new replacement power supply cord contact WindChaser Products Customer Service at:

(800)405-2943 or e-mail at: custserv@windchaserproducts.com.

Do not use The TEST and RESET Buttons as an on / off switch. They are only meant to be used to periodically

check the LCDI plug.

10

3

Page 5
Image 5
WindChaser Products PACRWC-HP instruction manual Condensation Elimination System, Long Term Storage

PACRWC-HP specifications

WindChaser Products has set a new standard in the realm of renewable energy solutions with the introduction of the PACRWC-HP, a high-performance wind turbine designed for efficiency, reliability, and advanced technology integration. This innovative product caters to both residential and commercial applications, making it an ideal choice for those seeking sustainable energy sources.

One of the standout features of the PACRWC-HP is its advanced energy capture system. The turbine is engineered with precision blades that maximize wind energy conversion while minimizing noise generation. This design ensures optimal performance even at low wind speeds, making it suitable for various environments, from urban settings to rural landscapes. The aerodynamic profile of the blades contributes to higher efficiency and durability, guaranteeing a longer service life.

The PACRWC-HP is built with a robust and corrosion-resistant structure, designed to withstand harsh weather conditions and provide reliable power generation year-round. The materials used in its construction are lightweight yet incredibly strong, enhancing the turbine’s overall performance and longevity. Furthermore, the turbine's compact design allows for easy installation and maintenance, saving both time and resources for users.

Integrating cutting-edge technology, the PACRWC-HP is equipped with a smart grid-compatible inverter system. This allows for seamless integration with existing electrical systems and optimizes energy output based on real-time wind conditions. Users can easily monitor and manage their energy production through a user-friendly digital interface, providing valuable insights into performance metrics and energy consumption.

Another notable characteristic of the PACRWC-HP is its noise-reduction technology, which ensures that the turbine operates quietly, making it ideal for residential areas where noise pollution is a concern. This feature does not compromise efficiency, ensuring that users can benefit from renewable energy without disturbing their environment.

Moreover, WindChaser Products emphasizes sustainability in its operations, using eco-friendly manufacturing processes to produce the PACRWC-HP. This commitment to green practices aligns with the increasing demand for environmentally friendly solutions in energy production.

In summary, the WindChaser Products PACRWC-HP stands out in the wind turbine market for its exceptional energy capture capabilities, robust construction, advanced smart technology, and commitment to sustainability. With its user-centric design and versatility, the PACRWC-HP is poised to become a leading choice for anyone looking to harness the power of wind in a responsible and efficient manner.