MAINTENANCE
Wire Terminal

MAINTENANCE

￿WARNING:

ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS.

VACUUM MOTOR REPLACEMENT

1.Turn off all switches and unplug machine.

2.Remove recovery tank.

3.Locate the vacuum motor wires and disconnect at the connector.

4.Remove the vacuum motor.

5.Reverse process to install vacuum motor.

Vac Motor Carbon Brushes Replacement

 

End Cap

Carbon Brushes

WARNING: The green

 

ground wire must be

 

attached for safe

 

operation.

 

See wiring diagram.

Note: When replacing carbon vac motor brushes loosen wire terminal BEFORE removing screws on bracket.

If armature commutator is not concentric, extremely pitted, or grooved the motor will need to be replaced or sent to a qualified service center to restore vac performance.

SOLUTION PUMP REPLACEMENT

1.Turn off all switches and unplug the machine.

2.Remove recovery tank.

3.Remove solution hoses from fittings in pump.

4.Remove the (2) screws that fasten the pump to the frame.

5.Reverse process to install pump.

Important:

These brushes wear quicker as the length shortens due to increased heat.

Spring inside brush housing will damage motor if brushes are

allowed to wear away completely.

Wire

Terminal

Note:

Place stop in groove.

VACUUM MOTOR REPLACEMENT 3/8

Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" long.