MAINTENANCE
4.SCRUB BRUSHES
There are four different types of brushes available to cover applications from cleaning heavily soiled floors to polishing. A pad driver is also available to take advantage of the many cleaning pads on the market. Please refer to the following to assist in selecting the proper brush or pad for the work at hand.
UNCOATED FLOORS
Aggressive Grit is a nylon fiber impregnated with silicone carbide grit. It grinds away stain, soil, and removes surface material.
Mild Grit is a less aggressive silicone carbide grit suitable for cleaning medium soil conditions. Advantages are faster ground speed than nylon bristles on light solid applications.
Polypropylene is a
FINISHED FLOORS
Nylon bristles are used in a variety of applications on coated or uncoated surfaces.
White Pads (Polishing) are used for dry polishing to achieve a
Red Pads (Buffing) are used for
Blue Pads (Scrubbing) are used for
Black Pads (Stripping) are used for easy and complete removal of old floor waxes/finishes. They will quickly remove ground in dirt, black heel marks, and spills. When used with the proper stripper, this pad leaves the floor clean and ready for finishing.
The scrub brushes should be checked before each days work for wire, string, wear and damage.
REPLACING OR INSTALLING SCRUB BRUSHES
1.With the scrub deck up, turn “OFF” the machine.
FOR SAFETY: Before leaving or servicing the machine; stop on level surface, turn OFF machine and remove key.
2.Remove the brush cover shrouds.
3.Locate release lever on top of brush or pad driver. Rotate release lever
4.To reinstall, center the brush driver under the brush drive hub. Raise until it contacts brush driver assembly. Turn clockwise until release lever plate locks into position.
5.Replace the brush cover shrouds.
NOTE: Check that release plate is completely closed and pad/brush is securely attached. Damage to driver or brush could occur.
5. RECOVERY TANK FLOAT SHUT-OFF
When water is no longer being vacuumed from the floor and the vacuum fan is operating, the ball float has engaged. The vacuum motor will not vacuum water with recovery tank full. The recovery tank must be drained.
1.The float
2.To clean the float
3.To remove the float
4.To install, place one hand on the tube, and then tilt and push the float screen assembly over the barb on the tube.
CUTTER 24V 86039070 04/10/07 | |
|