PROBLEM

PROBLEM

Machine will not run

Electrical shock

Repeated circuit breaker tripping

Excessive vibration

Pad does not turn but motor is running

CAUSE

Circuit breaker tripped in building.

Power switch failure.

Tripped circuit breaker.

Faulty power cord.

Fuse in motor is blown.

Equipment not grounded.

Receptacle not grounded.

Internal wiring problem

Mechanical problem.

Faulty circuit breaker.

Pad not centered.

Damaged or unevenly worn pad.

Damaged pad driver.

Shear coupling has failed.

TROUBLESHOOTING

SOLUTION

Check and reset.

Test switch for continuity and replace if necessary.

Reset.

Replace.

Replace. CAUTION: To reduce the risk of electrical shock, unplug the machine before opening fuse holder. Fuse will only open under extreme conditions. Investigate cause before replacing.

Follow grounding instructions exactly.

Have an electrician inspect building’s wiring.

Ensure that the machine wiring matches the appropriate wiring diagram. Replace any wires or components that are short-circuiting.

Higher amp draws indicate a mechanical problem, find the problem before using the machine.

Test circuit for continuity. Replace circuit breaker if necessary.

Re-center pad.

Replace pad. Do not rest machine on pad when not in use.

Replace.

Replace coupling.