Planning Information
Pro Island Ventilation Hood
M O D E L P I 5 4 3 4 1 8 ( R )
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications for overall dimensions and installation specifics.
Wolf Pro island ventilation hoods are recom- mended for use with any Wolf cooking appli- ance. The hood must overlap the cooking surface by a minimum of 3" (76) on either side.
Installation of all Pro ventilation hoods should be 30" (762) to 36" (914) from the bottom of the hood to the countertop. Follow the dimensions shown in the Installation illustration on page 4.
Wolf Pro island hoods are shipped without a blower assembly. Internal,
IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower.
Pro island hoods require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Placement of the electrical supply is not critical, as long as you provide enough 120 V AC, 60 Hz power cable to make the electrical connection. Location of electrical is centered through the top of the hood as shown in the Installation illustration on page 4.
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
Refer to the installation instructions shipped with each Wolf product for detailed specifica- tions. This information can also be found on our website, wolfappliance.com.
Dimensions in parentheses are in
millimeters unless otherwise specified. | 5 |