Planning Information
Pro 24" (610) Deep Wall Ventilation Hood
M O D E L P W 6 0 2 4 1 8 ( R )
D U C T I N G C O N S I D E R A T I O N S
Wolf Pro 24" (610) deep wall hoods are shipped without the blower assembly. Internal,
IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower.
Pro 24" (610) deep wall hoods have a vertical discharge. A horizontal discharge kit is available as a sales accessory.
The hood will operate most efficiently when ductwork does not exceed 50' (15 m) in length.
Local building codes may require the use of
IMPORTANT NOTE: Wolf Pro 24" (610) deep wall hoods must be vented to the outside. Use only metal ductwork.
Refer to the illustration below for ducting considerations for Pro 24" (610) deep wall hoods.
DUCTWORK INSTALLATION
THROUGH ROOF
ROOF CAP OR REMOTE BLOWER
10" (254) ROUND DUCT
TRANSITION 221/4"W x 9"D TO 10" ROUND 10"H (INCLUDING FLANGES)
SOFFIT OR CABINET
OR DUCT COVER
VERTICAL DISCHARGE
Ducting for Pro 24" (610) deep wall hoods.
18" (457)
HEIGHT OF HOOD
30" TO 36"
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
WALL HOOD
24" (610)
DEPTH OF HOOD
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
NOTE: HORIZONTAL DISCHARGE REQUIRES AN ACCESSORY KIT.
Dimensions in parentheses are in
millimeters unless otherwise specified. | 6 |