Install right side panels on both ovens. Connect the piping between the top oven and bottom oven. Pipe joint compound must be resistant to the action of propane gases.
The manual gas valve at the bottom of the control panel should remain off until all electrical connections are made and the ovens are checked or used.
LEVELING
Once the oven is in its permanent position, place a carpenter's level on the oven rack. If the oven is installed on legs, turn the adjustable feet in or out to level oven
CHIMNEY
LONG FLUE
EXTENSION
RIGHT ANGLED
FLUE EXTENSION
Fig. 4
ELECTRICAL CONNECTIONS
Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.
Appliances equipped with a flexible electric supply cord are provided with a
The 120 volt models are equipped with a cord and plug.
Refer to electrical wiring diagram located inside the right side panel; remove control panel for access.
Do not turn the power supply on until after the gas connections have been made and checked for leaks.
ELECTRICAL DATA
|
|
|
| Minimum Circuit Ampacity | |
Model | Volts | Hertz | Phase | Maximum Protective Device | |
|
|
|
| AMPS | |
|
|
|
|
| |
| 120 | 60 | 1 | 15 | |
|
|
|
|
| |
WKGHD | 50 | 1 | 15 | ||
|
|
|
|
| |
| 60 | 1 | 15 | ||
|
|
|
|
| |
WKGHC | 120 | 60 | 1 | 15 | |
|
|
|
| ||
50/60 | 1 | 15 | |||
| |||||
|
|
|
|
|
– 6 –