Wolf Appliance Company WWD30 dimensions Installation N O T E S

Models: WWD30

1 11
Download 11 pages 47.86 Kb
Page 8
Image 8

Planning Information

Warming Drawer

M O D E L W W D 3 0

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics.

Model WWD30 is shipped without any deco- rative drawer front. It must be installed with one of the accessory drawer fronts.Refer to the installation instructions provided with the warming drawer front for detailed specifications. These instructions can also be found on the Wolf website at wolfappliance.com.

Wolf recommends using a 33" (838) wide cabinet for the warming drawer with stainless steel drawer front. A minimum 30" (762) wide by 24" (610) deep cabinet is required. A minimum 33" (838) wide cabinet is required for the warming drawer with integrated drawer front.

The warming drawer with integrated drawer front can be used in an overlay application, or an inset panel application where it will be completely recessed into the cabinet. Keep in mind that the size of the custom panel for the warming drawer with integrated drawer front will vary according to the specific installation.

IMPORTANT NOTE: The inset panel application for the integrated drawer front requires the warming drawer to be recessed into the cabinet. A minimum 25" (635) deep cabinet is needed if you want the front panel to be flush with surrounding cabinetry.

The warming drawer platform must be able to support 200 lbs (91 kg). It must be a minimum of 1" (25) above the toe kick to allow for the overlap of the warming drawer trim.

IMPORTANT NOTE: A platform or anti-tip block must be installed to prevent the unit from tipping forward when the drawer is opened.

For undercounter installations, 231/2" (597) from the bottom of the warming drawer opening to the floor is recommended.

Model WWD30 requires a separate, grounded 120 V AC, 60 Hz power supply. The service should have its own 15 or 20 amp circuit breaker and a grounded 3-prong receptacle should be located within the reach of the 3' (.9 m) power cord. Locate electrical within the shaded area shown in the illustrations on pages 4–7.

The Wolf warming drawer may be installed below an induction, electric or gas cooktop, provided the warming drawer is fully enclosed, top and bottom. Refer to the cooktop sections of our website, wolfappliance.com.

Dimensions in parentheses are in

The Wolf warming drawer may be installed above or below a built-in single oven or below a double oven, provided the warming drawer is fully enclosed, top and bottom. Model WWD30 is designed and agency approved for installation with Wolf built-in ovens. Refer to the built-in oven sections of our website, wolfappliance.com.

When the warming drawer is installed below

abuilt-in oven, a minimum of 2 3/8" (60) between warming drawer and oven openings—11/2" (38) for integrated drawer front—is required for place- ment of the anti-tip block. To allow the warming drawer trim and the built-in oven trim to meet, a 7/8" (22) platform may be used to separate the two openings. This will act as the support platform for the oven and the anti-tip device for the warming drawer.

IMPORTANT NOTE: Additional clearance between warming drawer and oven openings may be required. Check that oven supports do not obstruct the interior dimensions required for the warming drawer.

IMPORTANT NOTE: When the warming drawer is installed above a built-in oven, a 7/8" (22) platform is required to allow for clearance of overlaps.

IMPORTANT NOTE: In an overlay application for the integrated drawer front, the amount of space between warming drawer and oven openings may need to be increased depending on the size of the overlay panel and the amount of overlap.

The warming drawer with stainless steel drawer front may be installed next to or above another Wolf warming drawer.

The Wolf warming drawer is designed and safe for use in outdoor applications. When installed outdoors, a ground fault circuit inter- rupter (GFCI) is required to reduce the risk of electrical shock. All other aspects of the installa- tion are identical for indoor and outdoor use.

You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.

The Wolf warming drawer may be installed in combination with a built-in single oven and microwave oven with trim. Be sure that the drawer front matches the series of oven and microwave trim you are using in your design. Refer to pages 9–11 for specifications.

Refer to the installation instructions shipped with each Wolf product for detailed specifications.

millimeters unless otherwise specified.

8