Hanging Mount

Plug Screw

Figure 7. Plug screw.

Figure 8. Eye bolt correctly seated.

Hanging Mount

To make the unit operate at the optimum height of 7 feet from the floor, you can install the air filter unit in your shop by hanging it by chain, cable, or steel strapping.

Get lifting assistance before installation. At 55 pounds, the Model W1690 air cleaner is a heavy load.

ONLY hang the air cleaner to load bearing ceiling supports or joists that can hold at least 100 lbs. DO NOT mount the unit to sheet rock, pressboard, paneling, or honeycomb ceiling panels with expansion-type fasteners like the ones shown in Figure 10. The fasteners can tear out and the air cleaner can fall. Ignoring this warning can result in severe injury or death.

To install the air cleaner for hanging mount operation, do these steps:

1.Install four chain, cable, or steel strapping lines to your ceiling from capable ceiling studs or supports. When the lines hang down freely they should be 1514" from left-to-right and 2412" from front-to-rear.

2.Remove the plug screw. Retain the screws because if you remove the eye bolts for the flush mounting configuration, you must reinstall these screws to seal the air cleaner unit. See Figure 7.

3.Thread the eye bolt completely into the air filter unit until the jam-nut shoulder contacts the air filter unit. See Figure 8.

4.Tighten the eye bolt until it is snug against the air filter unit.

5.Repeat Steps 2 through 5 on the three remaining eye bolts.

6.Raise and secure the air cleaner eye bolts to the four hanging lines.