Troubleshooting
OPERATION
Use this troubleshooting chart to solve any common problems with your Model W1690 Air Cleaner.
SYMPTOM | POSSIBLE REASON | HOW TO REMEDY |
The air | The power supply circuit breaker is tripped. | Correct the cause for high current draw and |
cleaner |
| close the circuit breaker. |
does not |
| Replace the blown fuse in the control panel. |
operate at | No power to the control panel. | |
all. |
|
|
| Wiring is at fault. | Repair, replace wires, plugs and cables as |
|
| applicable; and make sure all electrical plugs |
|
| and connections are secure. |
| The control panel circuit board is at fault. | Replace the circuit board. |
| The motor is at fault. | Replace the motor. |
|
|
|
The remote | The remote control has no power. | Install or replace the batteries. |
control does |
|
|
not operate | The signal path is obstructed. | Make sure the signal path is clear to the |
the air |
| infrared remote control sensor on the control |
cleaner but |
| panel. |
the control |
|
|
panel | The remote control is at fault. | Replace the |
operates |
|
|
fine. | The control panel circuit board is at fault. | Replace the control panel circuit board. |
|
|
|
The air | The filters are wet or clogged. | Replace the primary filter and clean the |
cleaner CFM |
| secondary filter. |
output is |
|
|
reduced. | The airflow path is obstructed. | Remove obstructions or add ducting. |
| The control panel circuit board is at fault. | Replace the control panel circuit board. |
| The motor is at fault. | Replace the motor. |
|
|
|
The air | The mounting is loose. | Tighten the flange brackets and reinstall the |
filter unit is |
| air cleaner unit. |
noisy or |
|
|
vibrates. | The unit is not level. | Level the air cleaner unit. |
| The fan or motor is loose. | Unplug the unit, remove the filters, and |
|
| tighten all loose fasteners. |
|
|
|