Electrical Requirements

SAFETY

110V Operation

The SHOP FOX® W1708 has a 1 HP, 110V, 60 Hz motor that draws approximately 10 amps under load.

Use a 15 amp circuit breaker in a circuit that has wiring rated to handle this amperage draw. Keep in mind that a circuit being used by other machines or tools at the same time will add to the total load being applied. Add up the load ratings of all the machines on the circuit. If this number exceeds the rating of the circuit breaker or wiring, use a different circuit.

Extension Cords

When it is necessary to use an extension cord, follow the guidelines below:

Use cords rated for Standard Service

Never use cords longer than 100 feet

Use cords with 16 gauge wire

Always use cords with a grounding pin

Never use damaged cords

Grounding

This machine must be grounded! If your outlet does not accommodate a ground pin (Figure 2), have the outlet replaced by a qualified electrician or have an appropriate adapter installed and grounded properly. An adapter with a grounding wire does not guarantee that the machine will be grounded. A ground source must be verified!

NEVER remove the grounding pin from any plug and always make sure all wiring to the

machine is grounded before

operating. Any electrical

outlet and circuit you plug your machine into must be grounded. Serious injury may occur if this warning is ignored!

DO NOT replace the circuit breaker with one rated at a higher amperage or damage to the circuit may occur.

Figure 2. 110V plug and outlet.

-8-

Page 10
Image 10
Woodstock W1708 instruction manual Electrical Requirements, 110V Operation, Extension Cords, Grounding