-20-
W1755 6" Parallelogram Jointer
OPERATIONS
This section covers the basic controls used during routine
operations.
ON/OFF Switch (Figure 26): Starts and stops the motor.
After the OFF paddle is pushed, the switch may need to
be reset before the next operation by lifting the paddle
and fully depressing the STOP button.
Table Movement: To move the infeed table, loosen the
table lock (Figure 27), move the table with the table
lever, then tighten the table lock. The infeed table will
only move through the preset range of the positive stops.
To adjust the infeed table positive stops, refer to Setting
Infeed Table Height on Page 36.
The outfeed table is preset with positive stops so no
range of movement is allowed (if it gets accidentally
unlocked it will not move). To adjust the outfeed table
positive stops, refer to Setting Outfeed Table Height on
Page 35.
Fence Movement: The fence has a lock handle that keeps
it in position (Figure 28). To move the fence, loosen the
lock handle and slide the fence where needed.
Fence Tilting: The tilt lock (Figure 28) secures the fence
at any position in the available range. The plunger locks
into an indexing ring to easily set the fence tilt to 90°.
Positive stops stop the fence at 45° inward and 45° out-
ward, for common 45° bevel cuts. Even when the fence
is resting against the positive stops, the tilt lock must be
tightened before cutting.
Basic Controls
Figure 26. Motor operation controls.
OFF Button
START Button
Figure 27. Table control locations.
Outfeed Table
Lever
Figure 28. Fence lock, tilt lock, and stop
block locations.
Fence
Lock Handle
Fence Tilt
Lever
Infeed Table
Lever
Tilt Lock
Plunger
Table Locks