Menu Details
The following is an explanation of functions and optional settings which are accessed via the various menus displayed.
1. POWER UP SCREENS
When you connect the power supply to AC power, the following screens will appear on the display.
1.The INTRODUCTION screen will scroll through the software version and other information.
2.The ROLLCALL screen shows when the power supply interrogates the color changers and other components connected to the power supply. This is the time the color changers "check in" with the power supply.
2. RUN SCREEN LOOP
The display alternates between three screens.
The first is " 1
The second screen is " DMX OK " if the DMX signal is being properly received. It is " NO DMX " if the DMX signal is not being properly received.
The third screen is " *ALERTS* " if there are any alert conditions to report.
3. ALERTS / ERROR MESSAGES
The power supply will display "alert messages" indicating a condition a service person may want to know about.
The alert messages and meanings are as follows:
Note: the "xxx" after each message is the DMX channel to which the message applies.
"Pstn xxx" - Gel position error - a difference exists between the commanded gel position and the actual gel position.
"VDC xxx" - Color changer voltage is below 17 volts DC.