RAD Data comm ASMI-450 operation manual Configuration Error Messages

Models: ASMI-450

1 117
Download 117 pages 38.23 Kb
Page 87
Image 87
4.7 Configuration Error Messages

ASMi-450 Control from the Control Port

4.7 Configuration Error Messages

The ASMi-450 provides configuration error messages for the control terminal user. The configuration messages have the format ERROR, followed by a two- digit code. The ASMi-450 will display a short description of the error message after the ERROR code.

The error messages are explained below.

ERROR 01

ILLEGAL

LOOP COMBINATION

 

Illegal combination of loopbacks: you are trying to activate simultaneously

 

local and remote loopbacks. Only one loopback can be connected at a time.

ERROR 02

REM REM

LOOP WHILE SYNC LOSS

 

You are trying to activate REM REM loopback while synchronization is lost.

ERROR 03

ILLEGAL

CLOCK MODE ON REMOTE SIDE

 

You are trying to select the internal clock mode at the remote side.

ERROR 04

LOOP IS

NOT ACTIVE

 

You are trying to disconnect a loopback that is not active.

ERROR 06

ILLEGAL

NODE NUMBER

 

You are trying to select a node number greater than 255.

ASMi-450 Installation and Operation Manual

4-29

Page 87
Image 87
RAD Data comm ASMI-450 operation manual Configuration Error Messages