RAD Data comm ASMI-450 operation manual LCD Configuration Error Messages

Models: ASMI-450

1 117
Download 117 pages 38.23 Kb
Page 57
Image 57
3.8 LCD Configuration Error Messages

Front-Panel Operating Instructions

3.8 LCD Configuration Error Messages

The ASMi-450 detects configuration errors and displays a CONFIG

ERROR XY message. The code XY identifies the error. You will find below the list of error messages and instructions that will help you correct the problem.

CONFIG ERROR 1 Illegal combination of loopbacks: you are trying to activate simultaneously local and remote loopbacks. Only one loopback can be connected at a time.

CONFIG ERROR 2 You are trying to activate the REM REM loopback while synchronization is lost.

CONFIG ERROR 3 CONFIG ERROR 4 CONFIG ERROR 5

You are trying to select the internal clock mode on the remote side.

You are trying to disconnect a loopback that is not active.

You are trying to change a parameter from the front panel when the password is enabled.

CONFIG ERROR 6 You are trying to select a node number greater than 255.

ASMi-450 Installation and Operation Manual

3-17

Page 57
Image 57
RAD Data comm ASMI-450 operation manual LCD Configuration Error Messages