ASMi-450 Control from the Control Port

Table 4-B. Control Terminal Alarm Messages

Alarm No.

Alarm Syntax

Meaning

State

Time

 

 

 

 

 

 

 

 

 

 

1

LOCAL DB

The data base currently stored in the non-

[ON]

hh:mm:ss

 

CHECKSUM ERROR

volatile memory of the local ASMi-450 is

 

 

 

 

corrupted. Message can appear only upon

 

 

 

 

power-up

 

 

2

LOCAL ALARM

The alarm buffer of the local ASMi-450 is

[ON] [OFF]

hh:mm:ss

 

BUFFER OVERFLOW

full, and new alarms overwrite the older

 

 

 

 

alarms

 

 

3

LOCAL SELF TEST

A fault has been detected in the local

[ON]

hh:mm:ss

 

ERROR

ASMi-450 during the power-up self-test

 

 

4

LOCAL HARDWARE

A hardware fault has been detected in the

[ON]

hh:mm:ss

 

FAILURE

local ASMi-450

 

 

5

LOCAL PSWRD

Section PSWD of switch S1 of the local

[ON]

hh:mm:ss

 

SWITCH IS ON

ASMi-450 is set to ON

 

 

6

LOCAL SP-PAR

Section DEF SP of switch S1 of the local

[ON]

hh:mm:ss

 

SWITCH IS ON

ASMi-450 is set to ON

 

 

7

LOCAL DB-INIT

Section DB INIT of switch S1 of the local

[ON]

hh:mm:ss

 

SWITCH IS ON

ASMi-450 is set to ON

 

 

8

LOCAL REAL TIME

The battery that powers the local

[ON]

hh:mm:ss

 

CLOCK BATTERY

ASMi-450 internal real-time clock when

 

 

 

FAILURE

ASMi-450 is not powered has failed

 

 

9

LOCAL REVERSE

Reversed loop polarity has been detected

[ON]

hh:mm:ss

 

POLARITY

by the local ASMi-450

 

 

10

LOCAL SIGNAL LOSS

Loss of HDSL line input signal at the local

[ON] [OFF]

hh:mm:ss

 

 

ASMi-450

 

 

11

LOCAL SYNC LOSS

The local ASMi-450 lost synchronization

[ON] [OFF]

hh:mm:ss

 

 

to the HDSL line signal

 

 

12

LOCAL LOW QUALITY

The CRC-6 error rate detected on the

[ON]

hh:mm:ss

 

ALARM

incoming HDSL signal exceeds 10-7

 

 

13

LOCAL TRANSMIT

A slip has been detected on the local

[ON]

hh:mm:ss

 

SLIP

transmit path

 

 

14

LOCAL RECEIVE SLIP

A slip has been detected on the local

[ON]

hh:mm:ss

 

 

receive path

 

 

15

LAN NOT CONNECTED

No data is received from the user's port

[ON] [OFF]

hh:mm:ss

 

 

(for ASMi-450 version with serial data

 

 

 

 

port).

 

 

 

 

or

 

 

 

 

The Ethernet interface is not connected to

 

 

 

 

an operating LAN (at least one station

 

 

 

 

must be active on the LAN)

 

 

ASMi-450 Installation and Operation Manual

4-17

Page 75
Image 75
RAD Data comm ASMI-450 operation manual Alarm No Alarm Syntax Meaning State Time