ASMi-450 Control from the Control Port

Notes

In addition to the parameters listed in Section 3-5, the following parameters can be programmed only from the terminal:

PWD

Password protection: select YES or NO

LOG_OFF

Idle disconnect time:

 

NO

automatic session disconnection disabled.

 

10_MIN

automatic disconnection after ten minutes if no input

 

 

data is received by the ASMi-450.

CTS

Determines CTS state:

 

ON

The CTS line is always ON (active).

 

=RTS

The CTS line follows the RTS line.

DCD_DEL

With ASMi-450 control port defined as DTE, indicates delay (in

 

msec) between DCD=ON and the sending of data.

 

Values: 0, 10, 50, 100, 200, 300 msec.

POP_ALM

Controls the automatic display of alarms in the terminal

 

YES

The terminal automatically displays every 10

 

 

minutes the alarm status (or whenever an alarm

 

 

changes state to ON)

 

NO

The automatic display feature is disabled

DSR

Determines the DSR state:

 

ON

The DSR line is continuously on. It will switch to

 

OFF

for five seconds after the DTR line is switched OFF.

 

DTR

The DSR line tracks the DTR line. When

 

 

INTERFACE=DTE, the DSR line will switch to ON

 

 

for five seconds when the RI line is ON while the

 

DTR

line is OFF.

AUXILIARY

Selects the management mode supported by the control port of

DEVICE

the ASMi-450:

 

TERMINAL management by means of a supervision terminal.

 

NMS_SLIP

management by means of Telnet host, or an

 

 

SNMP network management station.

6.After the desired parameter values are selected, press <CR> to end. The ASMi-450 will display the TIME and DATE fields, followed by the ASMi-450 prompt.