2. The password entry screen appears, e.g.:
NEW PASSWORD (4 to 8 CHARS) =
CURRENT PASSWORD = 'password'
where 'password' is the current password.
3.Type the required password. Carefully check that the specified password has been indeed typed in, and then press <CR>. The 
Note
Before entering a new password, make sure that the PSWD section of the 
DEF SP----------------------------------------------------------------------------------------- 
Purpose
Format
Use
Assign values to control port parameters. See Section 
DEF SP
1. Type
DEF SP<CR>
2.The first page of the control port parameters data form is displayed. A typical form is shown below. The form presents the current parameter values as defaults.
SPEED  | DATA  | PARITY  | INTERFACE  | CTS DCD_DEL  | DSR  | 
AUTO  | 8  | NO  | DCE  | =RTS 0_MSEC  | ON  | 
3.Change the parameter values as follows:
∙Bring the cursor to the beginning of the first field to be changed by pressing the space bar.
∙To change the selected field, press F or B to scroll among the available selections.
∙When the desired selection is displayed, press the space bar to move to the next field.
4.When done, press <CR> to display the next page of control port parameters. A typical form is shown below.
POP_ALM  | PWD  | LOG_OFF  | AUXILIARY DEVICE  | 
NO  | NO  | NO  | TERMINAL  | 
5. Repeat the procedure given in Section 3 above to select new parameter values.