Introduction
1.3 Technical Specifications
HDSL Interface
Signal Format
Line Type
Nominal Impedance
Transmit Pulse Shape
Transmit Signal Power
Loop Loss
Typical Range (AWG 24 Wire (0.5 mm))
392kbaud
584kbaud
Return Loss (Relative to 135Ω)
Loop Loss
Noise Margin
2B1Q line coding
One unconditioned, unloaded twisted pair 135Ω
Per ANSI
+13 dBm
−35 dB max. at 200 kHz (392 kbaud)
−31 dB max. at 150 kHz (584 kbaud)
5.7 km
4.5 km
−16 dB minimum, 40 kHz to 200 kHz @ 392 kbaud
−16 dB minimum, 25 kHz to 317 kHz @ 584 kbaud
−35 dB maximum at 200 kHz (392 kbaud)
−31 dB maximum at 150 kHz (584 kbaud)
−6 dB at 392 kbaud
−3.3 dB for 584 kbaud
Equalizer | Automatic adaptive equalizer |
Connector | |
User's Serial Data Port Interface |
|
Interface Type | V.35, |
| order |
Bit Rates |
|
n×64 kbps, up to 768 kbps | |
n×64 kbps, up to 1152 kbps | |
Interface Connectors |
|
V.35 | |
X.21 |