Diagnostics
Table 5-1. ASMi-450 Alarm Buffer Messages (Cont’d)
Message | Description | Corrective Actions | Alarm | |
Type | ||||
|
|
| ||
|
|
|
| |
|
|
|
| |
LOCAL PSWRD | Section PSWD of switch S1 of the | If it is no longer necessary to enforce | ON | |
SWITCH IS ON | local | the default password and node |
| |
|
| number, change setting to OFF |
| |
LOCAL REAL TIME | The battery that powers the local | Have the | ON | |
CLOCK BATTERY |
|
| ||
FAILURE | when |
|
| |
| failed |
|
| |
LOCAL RECEIVE | A slip has been detected by the local | Check the selection of clock sources | ON | |
SLIP | at the local and remote |
| ||
|
| units |
| |
LOCAL REVERSE | Reserved loop polarity has been | The | ON | |
POLARITY | detected by the local | operation |
| |
LOCAL SELF TEST | A problem has been detected during | Repeat | ON | |
ERROR | local |
| ||
LOCAL SIGNAL LOSS | Loss of HDSL line input signal at the | 1. Check the HDSL line. | ON/OFF | |
| local | 2. Perform |
| |
|
|
| ||
|
|
| ||
LOCAL | Section DEF SP of switch S1 of the | If it is no longer necessary to enforce | ON | |
SWITCH IS ON | local | the default control port parameters, |
| |
|
| change setting to OFF |
| |
LOCAL SYNC LOSS | Loss of synchronization on the | 1. Check the HDSL line | ON/OFF | |
| HDSL line at the local | 2. Perform |
| |
|
|
| ||
|
|
| ||
LOCAL TRANSMIT | A slip has been detected by the local | Check the selection of clock sources | ON | |
SLIP | at the local and remote |
| ||
|
| units |
| |
REM TRANSMIT SLIP | A slip has been detected by the | Check the selection of clock sources | ON | |
| remote | at the local and remote |
| |
|
| units |
| |
REM RECEIVE SLIP | A slip has been detected by the | Check the selection of clock sources | ON | |
| remote | at the local and remote |
| |
|
| units |
|