RAD Data comm ASMI-450 1. ASMi-450 Alarm Buffer Messages Cont’d, Description, Corrective Actions

Models: ASMI-450

1 117
Download 117 pages 38.23 Kb
Page 91
Image 91
Table 5-1. ASMi-450 Alarm Buffer Messages (Cont’d)

Diagnostics

Table 5-1. ASMi-450 Alarm Buffer Messages (Cont’d)

Message

Description

Corrective Actions

Alarm

Type

 

 

 

 

 

 

 

 

 

 

 

LOCAL PSWRD

Section PSWD of switch S1 of the

If it is no longer necessary to enforce

ON

SWITCH IS ON

local ASMI-450 is set to ON

the default password and node

 

 

 

number, change setting to OFF

 

LOCAL REAL TIME

The battery that powers the local

Have the ASMi-450 repaired

ON

CLOCK BATTERY

ASMi-450 internal real-time clock

 

 

FAILURE

when ASMi-450 is not powered has

 

 

 

failed

 

 

LOCAL RECEIVE

A slip has been detected by the local

Check the selection of clock sources

ON

SLIP

ASMi-450 in the receive path

at the local and remote ASMi-450

 

 

 

units

 

LOCAL REVERSE

Reserved loop polarity has been

The ASMi-450 continues normal

ON

POLARITY

detected by the local ASMi-450

operation

 

LOCAL SELF TEST

A problem has been detected during

Repeat self-test, and replace the

ON

ERROR

local ASMi-450 self-test

ASMi-450 if it fails the self-test

 

LOCAL SIGNAL LOSS

Loss of HDSL line input signal at the

1. Check the HDSL line.

ON/OFF

 

local ASMi-450

2. Perform self-test on the two

 

 

 

ASMi-450 and replace the

 

 

 

ASMi-450 that fails the self-test

 

LOCAL SP-PAR

Section DEF SP of switch S1 of the

If it is no longer necessary to enforce

ON

SWITCH IS ON

local ASMi-450 is set ON

the default control port parameters,

 

 

 

change setting to OFF

 

LOCAL SYNC LOSS

Loss of synchronization on the

1. Check the HDSL line

ON/OFF

 

HDSL line at the local ASMi-450

2. Perform self-test on the two

 

 

 

ASMi-450, and replace the

 

 

 

ASMi-450 that fails the self-test

 

LOCAL TRANSMIT

A slip has been detected by the local

Check the selection of clock sources

ON

SLIP

ASMi-450 in the transmit path

at the local and remote ASMi-450

 

 

 

units

 

REM TRANSMIT SLIP

A slip has been detected by the

Check the selection of clock sources

ON

 

remote ASMi-450 in the receive path

at the local and remote ASMi-450

 

 

 

units

 

REM RECEIVE SLIP

A slip has been detected by the

Check the selection of clock sources

ON

 

remote ASMi-450 in the receive path

at the local and remote ASMi-450

 

 

 

units

 

ASMi-450 Installation and Operation Manual

5-3

Page 91
Image 91
RAD Data comm ASMI-450 operation manual 1. ASMi-450 Alarm Buffer Messages Cont’d, Description, Corrective Actions, Type