ASMi-450 Control from the Control Port

RESET -----------------------------------------------------------------------------------------

Purpose

Reset the ASMi-450. This will cause the ASMi-450 to initialize, therefore the traffic

 

through the ASMi-450 will be disrupted until the ASMi-450 returns to normal operation.

 

For this function to operate the internal WD jumper (Section 2-4) must be set to ON.

Format

RESET

Use

1. To reset the ASMi-450, type:

 

RESET<CR>

TIME --------------------------------------------------------------------------------------------

Purpose

Set the time for the ASMi-450 internal real-time clock.

Format

TIME

 

Use

1.

Type

 

 

 

TIME<CR>

 

2.

The ASMi-450 sends the time entry form:

 

 

HOUR

= 12

 

 

MINUTE = 25

 

 

SECOND = 16

 

3.

If necessary, change the time as follows:.

 

 

∙ Bring the cursor to the beginning of the first field to be changed by pressing the

 

 

space bar.

 

 

∙ To change the selected field, press F or B to scroll among the available

 

 

selections.

 

 

∙ When the desired selection is displayed, press the space bar to move to the next

 

 

field.

 

 

4.

Set the time about one minute beyond the current time, and then press <CR> at the

 

 

correct instant. The ASMi-450 will display the TIME and DATE fields (note that

 

 

TIME has changed), followed by the ASMi-450 prompt.

ASMi-450 Installation and Operation Manual

4-25

Page 83