Diagnostics

Table 5-1. ASMi-450 Alarm Buffer Messages (Cont’d)

Message

Description

 

Corrective Actions

Alarm

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

REMOTE ALARM

More than 256 alarms entries have

Read the messages and then clear the

ON/OFF

BUFFER OVERFLOW

been written in the alarm buffer of

buffer:

 

 

the remote ASMi-450 since the last

-

If you are using the front panel,

 

 

clear command. New alarms are

 

delete all the event alarms by

 

 

overwriting the older alarms

 

selecting CLEAR.

 

 

 

-

From the control terminal, send the

 

 

 

 

CLR ALM command

 

REMOTE DB

The data base currently stored in the

1. Load the default configuration in

ON/OFF

CHECKSUM ERROR

non-volatile memory of the remote

 

the place of the current data base

 

 

ASMi-450 is corrupted. Message can

 

(from the control terminal, enter

 

 

appear only upon power-up

 

the INIT DB command)

 

 

 

2. Replace the ASMi-450

 

REMOTE DB-INIT

Section DB INI of switch S1 of the

If it is no longer necessary to enforce

ON

SWITCH IS ON

remote ASMi-450 is set to ON

the default data base parameter

 

 

 

values, change setting to OFF

 

REMOTE DTE NOT

No data is received from the remote

Check the remote LAN or DTE

ON/OFF

CONNECTED

user's port (for an ASMi-450 version

connection

 

 

with serial data port).

 

 

 

 

or

 

 

 

 

The remote Ethernet interface is not

 

 

 

 

connected to an operating LAN (at

 

 

 

 

least one station must be active on

 

 

 

 

the LAN)

 

 

 

REMOTE HARDWARE

Remote ASMi-450 technical failure

Replace the ASMi-450

ON/OFF

FAILURE

(failure of one of the internal

 

 

 

 

programmable components)

 

 

 

REMOTE LOW

The far-end block error rate (FEBE)

1. Check the HDSL line connecting

ON

QUALITY ALARM

reported via the HDSL line exceeds

 

the two ASMi-450 units.

 

 

10-7

2. Perform self-test on the two

 

 

 

 

ASMi-450 and replace the

 

 

 

 

ASMi-450 that fails the self-test

 

REMOTE PSWRD

Section PSWD of switch S1 of the

If it is no longer necessary to enforce

ON

SWITCH IS ON

remote ASMI-450 is set to ON

the default password and node

 

 

 

number, change setting to OFF

 

REMOTE REAL TIME

The battery that powers the remote

Have the ASMi-450 repaired

ON

CLOCK BATTERY

ASMi-450 internal real-time clock

 

 

 

FAILURE

when ASMi-450 is not powered has

 

 

 

 

failed

 

 

 

5-4

ASMi-450 Installation and Operation Manual

Page 92
Image 92
RAD Data comm ASMI-450 operation manual Remote Alarm