Troubleshooting
Specs
Serial Data Port Characteristics Ethernet Interface Characteristics
Install
Error codes
Warranty
Starting the Configuration
Appendix A Connector Wiring
Trouble Symptoms
Reset
Page 58
Image 58
Front-Panel
Operating Instructions
Notes
3-18
ASMi-450
Installation and Operation Manual
Page 57
Page 59
Page 58
Image 58
Page 57
Page 59
Contents
RAD data communications
High-Speed HDSL Modem Installation and Operation Manual
ASMi-450
RAD data communications
Limitation of Warranty
Warranty
Exclusive Remedies
Safety Status
Safety Warnings
Telecommunication Safety
Ports
FCC-15 User Information
Regulatory Information
Warning per EN
Declaration of Conformity
Page
Chapter 1 Introduction
Contents
Chapter 2 Installation
Chapter 3 Front-Panel Operating Instructions
ASMi-450 Installation and Operation Manual
Contents
Chapter 5 Diagnostics
Chapter 4 ASMi-450 Control from the Control Port
5.4 Power-Up Self-Test
Appendix A Connector Wiring
Appendix C Installation in 19 Racks
5.5 Troubleshooting Instructions
Contents
ASMi-450 Installation and Operation Manual
List of Figures
ASMi-450 Installation and Operation Manual
ASMi-450 Installation and Operation Manual
List of Figures
ASMi-450 Installation and Operation Manual
List of Tables
xiii
ASMi-450 Installation and Operation Manual
List of Tables
1. Starting the Configuration
Quick-Start Guide
Preliminary Preparations Starting Procedure
Function
2. Configuration Procedure
Use the Command
Terminal Type
Display Commands
3. Command Index
Configuration
Control Commands
Quick-Start Guide
ASMi-450 Installation and Operation Manual
Quick-Start Guide
Purpose and Main Features
Chapter Introduction
1.1 Functional Description
Figure 1-A. Typical Application for ASMi-450 with Data Interface
Serial Data Port Characteristics Ethernet Interface Characteristics
Figure 1-B. Typical Application for ASMi-450 with Ethernet Interface
HDSL Subsystem Characteristics
∙ ASMi-450 Unit Configured as Central Unit LTU. The ASMi-450 unit
System Timing
Local Control
Control of ASMi-450 Operation
Remote Management
Introduction
Physical Characteristics
Test and Diagnostics Capabilities
Alarms
Power Requirements
1.2 Operating Environment
Transmission Media HDSL Line Signal
Quaternary Symbol
Binary Digits
HDSL Signal Structure HDSL-Related System Functions
HDSL Interface
1.3 Technical Specifications
Users Serial Data Port Interface
Ethernet Interface
Indicators
Diagnostics
Timing Modes
Power
Physical Characteristics
Environment
Chapter Installation
2.1 General
2.3 Site Requirements
Power Users Port Connections HDSL Line Connections
2.2 Unpacking
Front and Rear Panel Clearance Ambient Requirements
Warning - Electrical Shock Hazard
2.4 ASMi-450 Configuration Information
General
Opening ASMi-450 Case
Switch S1
Jumper and Switch Location and Functions
Figure 2-1. Identification of Cover Screws
Installation
Figure 2-2. ASMi-450 Internal Settings
ASMi-450 Installation and Operation Manual
EPROM
Jumper R/C
Internal Settings Procedure Reinstalling ASMi-450 Cover
Jumper FGND/GND
Connector Location Grounding
Installation
AC Power Connection
Power Connection Users Port Connections
DC Power Connection
HDSL Line Connections Control Port Connection
Chapter Front-Panel Operating Instructions
3.1 Scope
Control or Indicator
3.2 Front Panel Controls, Connectors, and Indicators
Table 3-A. ASMi-450 Controls, Connectors and Indicators
Figure 3-A. ASMi-450 Front Panel
Indicator
Indicators
Table 3-B. Ethernet Interface Indicators
Ethernet Interface
3.3 Control of ASMi-450 Operation, General
General General Operating Instructions Display Functions
Test Functions
Configuration Parameters
Status Messages
Display
ASMi-450 Display
Using Front-Panel
Organization of
Push-buttons
If you make an incorrect selection, the selection is not accepted. In this case, you see a CONFIG ERROR message with a code number. The code indicates what is wrong. Section 3-8 explains the codes
Default EXT
3.4 System Configuration Parameters
ASMi-450 configured as central CNTR unit
ASMi-450 configured as remote REM unit
Designation
3.5 Control Port Configuration Parameters
Table 3-D. Control Port Parameters
Function
Turn-on Checking Current Operating Configuration
3.6 Operating Instructions
Display
Action
Display
Step
Action
Fault Indications
Step
Display
Configuration
3.7 Local Configuration Set-Up Procedure
Password
Procedure
Display
Step
Action
must be independently selected for each
Display
Specific Configuration Guidelines
Action
SYSTEM PARAMETER
PARITY
SP PARAMETERS
DATA
INTERFACE
3.8 LCD Configuration Error Messages
Front-Panel Operating Instructions
ASMi-450 Installation and Operation Manual
3-18
Chapter ASMi-450 Control from the Control Port
4.1 General
4.2 Hardware Requirements
Terminal Characteristics Communication Requirements
Handshaking Protocol
Request to Send RTS
Interface Type
Data Terminal Ready DTR
Clear to Send CTS
Ring Indication RI
AUTOBAUD Function
Data Set Ready DSR
4.3 Preparation for Use of Supervision Terminal
Internal Settings
Control Port Configuration
ASMi-450 Preparations Supervision Terminal Connections
4.4 ASMi-450 Supervision Language
Command Language Syntax Command Options
Command Protocol
Option
Index of Commands
Purpose
Table 4-A. ASMi-450 Command Set Index
Command
Options
CLR LOOP
4.5 ASMi-450 Command Set Description
CLR ALM
Purpose
DEF AGENT
CLR TST
DATE
Purpose
TELNETAPATHYTIME
DEF NAME
Display Fields
IPADDRESS
Purpose
DEF NODE
DEF PWD
Format
DEF SP
Purpose Format Use
Controls the automatic display of alarms in the terminal
Password protection select YES or NO
automatic session disconnection disabled
minutes the alarm status or whenever an alarm
Purpose
DEF SYS
DEF TERM
Format
Terminal Type
DSP ALM
Function
VT-52
Alarm Syntax
Table 4-B. Control Terminal Alarm Messages
Alarm No
Meaning
Alarm Syntax
Table 4-2. Control Terminal Alarm Messages Cont’d
Alarm No
Meaning
Alarm Syntax
Table 4-2. Control Terminal Alarm Messages Cont’d
Alarm No
DSP HDR TST
Display Format
DSP ST PORT
Purpose Format Use Display Format
Purpose Format Use Display Format
DSP ST SYS
EXIT
Purpose
Purpose
HELP
Purpose Format Use
Format
Format
Default Value
INIT DB
Parameter Designation
passwordCR
PASSWORD
PASSWORD
LOOP
Purpose
RESET
TIME
Format
ASMi-450 Control from the Control Port
Starting a Session Single ASMi-450
4-26
Control Session
Ending a Control Session
4.7 Configuration Error Messages
ASMi-450 Control from the Control Port
ASMi-450 Installation and Operation Manual
4-30
5.1 General
Chapter Diagnostics
Indicators Display
5.2 Status Indications and Messages
Message
Table 5-A. ASMi-450 Alarm Buffer Messages
Alarm
Description
Message
Table 5-1. ASMi-450 Alarm Buffer Messages Cont’d
Alarm
Description
Message
Table 5-1. ASMi-450 Alarm Buffer Messages Cont’d
Alarm
Description
Message
Table 5-1. ASMi-450 Alarm Buffer Messages Cont’d
Alarm
Description
LOOP LOCAL PORT
5.3 Test Functions
Test Functions
Figure 5-A. LOOP LOCAL PORT Loopback
Figure 5-B. LOOP REM REM PORT Loopback
LOOP REM REM PORT
TEST OPTIONS Operating Instructions
Step
Step
5.4 Power-Up Self-Test
Cont’d
Action
Trouble Symptoms
5.5 Troubleshooting Instructions
Table 5-B. Troubleshooting Chart
Probable Cause
Probable Cause
Table 5-2. Troubleshooting Chart Cont’d
Trouble Symptoms
Corrective Measures
Table A-1. RS-530 DCE Connector
Appendix A Connector Wiring
A.1 RS-530 DCE Connector and Adapter Cables
Designation
Designation
The V.36/RS-499/422 connector is a 37-pin D-type male connector
Table A-2. V.36/RS-449/422 DCE Interface Adapter Cable
Direction
Designation
A.2 V.35 DCE Connector
Table A-3. V.35 DCE Connector
Direction
Direction
A.3 X.21 DCE Connector
Designation
Function
Table A-5. LINE Connector, Pin Allocation
A.4 HDSL Line Connector
A.5 RS-232 V.24 Control Port Connector
Table A-6. Control Port Interface Signals
Designation
A.6 Ethernet Interface Connector
Table A-7. Ethernet Interface Connector
Direction
Appendix B SNMP Management
B.1 Scope
General SNMP Principles
B.2 SNMP Environment
SNMP Operations
MIB Structure
The Management Information Base
Read-only
MIBs Supported by the ASMi-450 SNMP Agent
Management Domains Under SNMP
Access Restriction Using SNMP Communities
SNMP Communities
Write
ASMi-450 Communities
Read
Trap
IP Address Structure
B.3 IP Environment
General IP Environment
Address Class
Often, the host portion is further sub-divided into two portions
B.4 SNMP Traps
Appendix C Installation in 19 Racks
C.1 General
C.2 Installation of Single Unit
Figure C-1. Installation of Single Unit in 19 Rack
C.3 Installation of Two Units
General Preparations
Fastening the Two Units
Installation Instructions for Compliance with EMC Requirements
ASMi-450