INIT DB ----------------------------------------------------------------------------------------

ASMi-450 Control from the Control Port

INIT DB ----------------------------------------------------------------------------------------

Purpose

Load a specified set of default parameters values instead of the user configuration (Table

 

 

4-3).

 

 

 

 

Format

INIT DB

 

 

 

Use

1. Type

 

 

 

 

 

INIT DB<CR>

 

 

 

 

2. The ASMi-450 will display the TIME and DATE fields followed by the ASMi-450

 

 

prompt.

 

 

 

 

 

Table 4-C. ASMi-450 Default Configuration Used with Control Terminal

 

 

 

 

 

 

 

Parameter Type

 

Parameter Designation

Default Value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PASSWORD

ASMI

 

 

 

 

 

NODE (node number)

0

 

 

 

General

 

CLEAR SCREEN

00000000

 

 

 

 

 

CURSOR HOME

00000000

 

 

 

 

 

CURSOR RIGHT

00000000

 

 

 

System

 

CLK_MASTER

EXT

 

 

 

 

ACTIVE TS

Maximum supported on the ASMi-450 model

 

 

 

 

 

 

 

 

 

 

SPEED

AUTO

 

 

 

 

 

DATA

8

 

 

 

 

 

PARITY

NONE

 

 

 

 

 

INT

DCE

 

 

 

SP

 

PWD

NO

 

 

 

(Control Port)

 

LOG_OFF

NO

 

 

 

 

 

CTS

=RTS

 

 

 

 

 

DSR

ON

 

 

 

 

 

DCD_DEL

0_MSEC

 

 

 

 

 

POP_ALM

NO

 

 

 

 

 

 

 

 

INIT F -------------------------------------------------------------------------------------------

 

 

 

 

Purpose

Resets the terminal control codes used to clear the terminal screen, to move the cursor to

 

 

the right, and to return the cursor to the home position to 0.