Front-Panel Operating Instructions

SP PARAMETERS

See parameter definitions in Section 3-5.

SPEED_BPS Select AUTO whenever feasible. In this case, start the communication with three Carriage Returns, to ensure positive identification of terminal data rate.

Note

The automatic baud rate recognition procedure must be repeated after the DTR line in the control port connector had been switched to OFF and then ON again.

DATA

Select the required number of data bits (same as on the

 

terminal).

PARITY

Select the required parity (same as on the terminal).

INTERFACE

∙ Select DCE when directly connected to the control

 

terminal.

 

∙ Select DTE when connected to a modem (future

 

option).

Note

The INTERFACE parameter only changes the direction of the interface control (handshaking) signals, but not the functions of the interface pins. Therefore, when connecting to a modem, it is necessary to use a cross cable.

3-16

ASMi-450 Installation and Operation Manual

Page 56
Image 56
RAD Data comm ASMI-450 operation manual SP Parameters