Specific

 

 

 

 

Front-Panel Operating Instructions

 

 

 

 

 

 

 

 

 

 

 

 

 

Step

Action

Key

Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

After completing the configuration actions,

SCROLL

The top row shows:

 

 

 

you can use steps 1, 2 to return to the

 

ALARM BUFFER

 

 

 

ALARM BUFFER.

 

 

 

 

 

If alarm messages are stored in the alarm

 

 

 

 

 

buffer, ALARM BUFFER will be

 

 

 

 

 

automatically displayed if no push-button is

 

 

 

 

 

pressed for one minute.

 

 

 

 

 

 

 

 

 

Specific

Configuration

Guidelines

This section presents specific configuration guidelines for the selection of parameter values. You may also wish to refer to Section 1-2, that provides a concise description of the ASMi-450 operating environment, including explanations for many of the relevant terms.

SYSTEM PARAMETER

See parameter definitions in Section 3-4.

CLK MASTER The selection can be made only at the unit configured as

 

CNTR.

 

 

∙ For connection to carrier lines, select EXT.

 

∙ For a point-to-point application with stand-alone

 

equipment at both link ends, you can also select INT.

 

∙ For ASMi-450 with Ethernet interface, select INT.

ACTIVE TS

∙ For ASMi-450 models with DCE interface, the

 

number of active time slots must be equal to the

 

multiplier of the basic data rate (64 kbps) which

 

yields the required user's data rate. The maximum

 

number of active time slots depends on the

 

ASMi-450 model:

 

5￿

ASMi-450/768: 12 time slots

 

5￿

ASMi-450/1152: 18 time slots

ETHERNET

Select the method used to handle the LAN traffic,

MODE

half-duplex (HALF_DUP) or full-duplex (FULL_DUP).

 

This parameter appears only for ASMi-450 version with

 

the Ethernet interface.

BRIDGING

Select FILTERED if you want to operate the E1 link as a

 

remote bridge (the recommended method). To operate the

 

link as a LAN extender (or repeater), select TRAN.

This parameter appears only for ASMi-450 version with the Ethernet interface.