RAD Data comm ASMI-450 Dsp Alm, Function, Terminal Type, VT-52, VT-100, Freedom-110, Format Use

Models: ASMI-450

1 117
Download 117 pages 38.23 Kb
Page 74
Image 74
VT-52

ASMi-450 Control from the Control Port

Function

 

 

Terminal Type

 

 

 

 

 

 

 

 

TV- 920

VT-52

VT-100

 

Freedom-110

Freedom-220

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clear Screen

1B2A0000

N/A

1B5B324A

 

1B2A0000

1B5B324A

Cursor Home

1E000000

1B480000

1B5B4800

 

1E000000

1B5B4800

Cursor Right

0C000000

1B430000

1B5B3143

 

0C000000

1B5B0143

 

 

 

 

 

 

 

Format

Use

DEF TERM 'terminal'

1.To configure the ASMi-450 for using the control sequences corresponding to a supported terminal, type:

DEF TERM 'terminal'<CR>

where 'terminal' stands for one of the types listed in the table above.

2.In response, you will see the new control sequences, in the format shown below:

New Control Sequences:

CLEAR SCREEN = hhhhhhhh

CURSOR HOME = hhhhhhhh

CURSOR RIGHT = hhhhhhhh

where h indicates hexadecimal digits.

DSP ALM --------------------------------------------------------------------------------------

Purpose

Display the contents of the alarm buffer. This buffer can contain up to 100 alarms.

Format

DSP ALM [Option]

Use

1. To display the complete contents of the buffer, type:

 

DSP ALM<CR>

 

2. To display the complete buffer contents and then clear the type-ON alarms, type:

 

DSP ALM /C<CR>

 

3. To display the complete buffer and then clear all the stored alarms, type:

 

DSP ALM /CA<CR>

Display

The contents of the alarm buffer are displayed as a table with four columns: the alarm

Format

number and alarm syntax (description), alarm state, and time of alarm occurrence. Each

 

block of alarms received from a ASMi-450 is preceded by a header. The header lists the

 

assigned node name and the node number of the ASMi-450 unit which sent the alarm

 

block, and thus it serves as an easily-identified separator between alarms transmitted by

 

different ASMi-450 units.

 

Table 4-2 lists all the alarm messages that can be displayed by the terminal.

4-16

ASMi-450 Installation and Operation Manual

Page 74
Image 74
RAD Data comm ASMI-450 Dsp Alm, Function, Terminal Type, VT-52, VT-100, Freedom-110, Format Use, Purpose, Display