Xantech CC62 installation instructions IR Rcvr Input Connector, Installation

Models: CC62

1 5
Download 5 pages 33.17 Kb
Page 3
Image 3

The CC62 should normally be plugged into an unswitched AC outlet. However, if the power to the CC62 is interrupted by a power failure or other reason, the internal memory will retain the last selected switched condition for each of the relays.

IR RCVR INPUT CONNECTOR

This 4-terminal input has electrical connections for +12V, GND (chassis ground), GND (IR signal ground) and IR IN (IR signal). The GND terminal closest to the IR IN terminal is provided so that, if needed, the IR signal ground can be isolated from the chassis ground. This isolation may be necessary in some instances to prevent ground loop problems, etc.

A special jumper, inside the CC62, gives you the option to make the grounds common or have them isolated. Refer to Fig. 3.

To gain access to this jumper, remove the eight screws that secure the top cover to the metal chassis. Carefully lift the cover

Jumper ON Position. (Common ground between GND and GND terminals - factory default setting)

JP1

LED1

PCB

Metal Chassis

JP1

LED1

PCB

off. When you have made the adjustment, reassemble in reverse order.

NOTE: When shipped from the factory, the jumper is installed in the ON (common) position.

Jumper OFF Position (Isolated Grounds).

No connection between the GND and GND terminals.

Fig. 3 Location and Adjustment of Grounding Jumper

CAUTION: When powering IR receivers and keypads directly from the CC62, you must leave the jumper installed in the ON position so that the two G terminals are connected in common. This provides the needed ground return for the IR signal.

Change the jumper to the OFF position only when powering IR source devices separately from the CC62 and there is a need for electrical isolation.

INSTALLATION

Typical applications for the CC62 are as follows:

To activate shade or drape pulls, projector lifts, screen drops, etc. Use Momentary On modes at relay #1 to close and at relay # 2 to open, if such devices require two separate dry contacts to operate.

To switch low voltage lighting or other devices: Use Toggle or the ON & OFF (pair) commands. Pair commands allow a known ON/OFF status from remote rooms where visual status is not possible.

Amplifier A/B switching: Each relay can be connected so that a stereo pair of speakers (in each remote room) can be switched between two AV receivers. This effectively creates a simple 2-zone system addressable from each room. Refer to Fig. 4.

Each remote control and keypad used in the system needs to be programmed with Toggle or Pair commands from the RC68+ to do the A/B switching. In addition, each room needs a dedicated learning remote or keypad having the RC68+ IR commands that operate the specific CC62 relay for each room.

NOTE: The CC62 is shown connected to Xantech 760-00 Match Maker room volume controls (Fig. 4) for individual room control. When set correctly, the Match Makers will provide the proper impedance match between the speakers and the amplifiers. See the 760-00 Installation Instructions for details.

Another important application of the CC62 is to provide IR-to-switch closures for a 590 Programmable Controller. This permits multiple sequenced commands to be generated from a single RC68+ IR command or to convert RC68+ commands to other brand commands. Fig. 5 illustrates such a system.

Up to 16 independent closures are possible by using as many as three CC62's with a 590-00. Use Momentary On programming.

 

 

 

 

 

 

 

3

 

CC62

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote Control Switchers

Page 3
Image 3
Xantech CC62 installation instructions IR Rcvr Input Connector, Installation