Xantech XT1 user manual RS232 Protocol

Models: XT1

1 16
Download 16 pages 28.59 Kb
Page 10
Image 10

Appendix 1

 

 

RS232 Protocol

 

 

Interface

 

 

Baud Rate :

9600

Stop Bit: 1

Data Bits :

8

Parity Bit: none

Transmission:

In ASCII codes

 

Format

<ZoneID><_><ProductID><_><Command><_><Parameter1><_><Parameter2><_><CR>

<Zone ID>

Is a number from 00 to 99, sending "00" selects all zones.

 

The maximum number is 99.

 

Zone ID is factory set at "0", but can be reassigned.

<Product ID>

For the XT1, the factory default setting for product ID is 10

<Command>

Is 1 to N, N may be in one or multiple digits as defined in the first column in the

 

table below

<Parameter1>

None, or is 1 to N, N may be in one or multiple digits as defined in the

 

"Parameter1" column below

<Parameter2>

None, or is 1 to N, N may be in one or multiple digits as defined in the

 

"Parameter2" column below

<_>

The fields are separated by an underscore "_"

<CR>

A character return to terminate the command line

<Zone ID>

If multiple T118 tuners are used in one application, the Zone ID of each tuner

 

shall be reassigned with a unique number.

In this way each tuner can be controlled individually via the RS232 port. Use command 14 in the following list to program a new Zone ID.

T118

Purpose

Parameter1

Purpose of Parameter1

Parameter2

Command

 

 

 

 

1

Power on/off

1

Power off

 

 

 

2

Power on

 

 

 

3

Toggle power on/off

 

2

Band switching

1

AM

 

 

 

2

FM

 

 

 

3

Toggle between AM/FM

 

3

Preset access

1 to N

1 for preset 1, 32 for preset #32

 

4

Direct frequency

87..107

Enter the integal part of a FM frequency

00..95

 

 

5..16

Enter the 1st or first two digits of an AM

 

 

tuning

frequency

00..99

 

 

10/16

XT1

 

Page 10
Image 10
Xantech XT1 user manual RS232 Protocol