High-input Voltage Shutdown If a defective battery charging system causes the battery voltage to rise to dangerously high levels, the Digital Inverter shuts down automatically. The over-voltage error code ‘E02’ will show on the digital display.

Overload Shutdown If you connect an AC load that is rated too high (see Table 3) or a load that draws excessive surge power, the Digital Inverter shuts down. The overload error code ‘E03’ will show on the digital display.

Overheating Shutdown The Digital Inverter shuts down automatically if it exceeds its safe operating temperature. The overheating error code ‘E04’ will show on the digital display.

Shutting the inverter off

If you are going to disconnect the battery, turn the inverter off first.

Turn the inverter off by holding the switch until the display turns off.

20

Page 24
Image 24
Xantrex Technology 400 W, 800 W, 200 W manual Shutting the inverter off