Troubleshooting Reference

This section describes problems, their symptoms, possible causes, and solutions.

Problem: The AC load will not operate. Digital display is off.

Possible Cause

Solution

 

 

Battery is defective.

Check battery and replace if required.

The inverter has been connected

Check connection to battery.

with reverse DC input polarity.

The inverter has likely been damaged and

 

needs to be repaired.

 

Have the unit repaired (not covered under

 

warranty).

Loose cable connections.

Check cables and connections.

 

Tighten as required.

Problem: The inverter will run some small loads, but not larger ones.

Possible Cause

Solution

Voltage drop across DC cables. Shorten cables or use heavier cables.