| INSTALLATION | |
|
| |
• Remove the positive (+) battery cable | If multiple battery banks are to be | |
terminal cover from the unit and attach the | charged, a battery bank selector switch can be | |
battery cable. Tighten the battery terminal bolts | installed, allowing the banks to be charged | |
to a torque value between 160 | either individually or simultaneously. A solenoid | |
and 180 | can also be used. The PathMaker Battery | |
the positive terminal. | ||
Combiner, by Xantrex, may be used to | ||
| ||
The negative | connect multiple battery banks. The | |
connected directly to the negative post of the | PathMaker battery combiner is available from | |
house or auxiliary battery bank or the ground | your Xantrex dealer. |
side of a current shunt. Tighten securely.
The positive (+) battery cable must be fused and connected to the positive post of the house or auxiliary battery bank, or through a selector switch to one or more battery banks.
A spark may be generated when the final battery connection is made. This is normal; do not be alarmed. However, do not make the final connection in the presence of flammable fumes.
If multiple batteries are used, the interconnecting jumper cables must be the
same AWG or larger as those connected to |
| |
the inverter/charger. |
| |
NOTE: If installing in a vehicle, do not use the | PathMaker 100, 2 Channel | |
vehicle frame as the negative conductor. | ||
PathMaker Models | ||
| ||
| 100 Amp, 2 Channel | |
| 100 Amp, 3 Channel | |
POSITIVE (+) | 200 Amp, 2 Channel | |
200 Amp, 3 Channel | ||
(Battery Cable | ||
| ||
Cover on) |
| |
NEGATIVE |
| |
(Battery Cable |
| |
Cover on) |
| |
Freedom 20 |
|
27