INSTALLATION EXAMPLES
Installation examples for the new Freedom 458 Series Inverter/ChargersShorepower configurations:Systems with one 30 Amp
Systems with two 30 Amp shorepower sources with optional generator
Systems with a 50 Amp 120 Volt
Systems with a 50 Amp 120/240 Volt
Single Input / Single Output Freedom 458 Model 10, 15, 20, 25, and 30 Single Input / Dual Output (Freedom 458 Model 15 S/D or 20 S/D only) Dual Input / Dual Output Freedom 458 Model 20 D/D, 25 D/D and 30 D/D
·Can be connected with single in /single out mode
·Can be connected with dual in / single out mode
·Can be connected with dual in / dual out mode
The following installation examples are the most commonly used applications involving specific shorepower connections, generator power options, and AC load configurations.
Freedom 458 DC Cable and Fuse General Guide
|
|
|
|
| Typical |
| Cable AWG by Length * | ||||||
Model |
| Fuse Size |
| DC Amps |
|
|
| ||||||
|
|
|
|
| |||||||||
| 200 A |
| 100 A |
| 2 |
| 2 |
| 1/0 |
| |||
| 200 | A |
| 150 | A |
| 1/0 |
| 1/0 |
| 2/0 |
| |
| 300 | A |
| 200 | A |
| 2/0 |
| 2/0 |
| 3/0 |
| |
| 300 | A |
| 250 | A |
| 2/0 |
| 3/0 |
| 3/0 |
| |
| 350 | A |
| 300 | A |
| 3/0 |
| 3/0 |
| 4/0 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*This guide is intended to provide general recommendations for fuse and cable sizing. Always consult Local and National Electrical Codes for proper fuse and cable size prior to installation.
The chassis grounding wire must be no smaller then 1 gauge under that of the Positive battery cable.