OPERATION

When the LED is blinking slowly (once per second), an over-current condition or a short circuit has occured. The system has shut OFF and will not automatically restart. Correct the fault condition and manually restart the system.

LOW BATTERY AND OVERTEMP/OVER-

LOAD - Red LEDs

When both LEDs are blinking, an AC backfeed has been detected. A backfeed occurs when AC power from an external source is connected to the output of the inverter. Inspect wiring for possible input/output wiring error. This condition will damage the unit and must be corrected before further operation.

TSC (Temperature Sensitive Charging)

This provides for the connection of a sensor to measure battery temperature for compensated charging. If no sensor is connected the charge voltage levels are set to defaults based on battery type.

OPTIONAL REMOTES

If using one of the remotes, refer to the installation instructions included with the remote.

Note: When a Freedom Remote Control Panel or Link is installed, the jumper included in the parts plastic bag is not used in the Auxiliary Switch Port (AUX SWITCH) on the front panel of the inverter/charger. See page 23 for more details.

 

Overtemp

 

Low

Remote TSC

Auxiliary Port

Battery

 