Connecting DC Cables

7.Before proceeding, make sure that the cable you have just installed connects the negative terminal of the inverter to the negative terminal of the battery.

WARNING: Explosion or Fire

Do not complete the next step if flammable fumes are present. Explosion or fire may result. Thoroughly ventilate the battery compartment before making this connection.

8.Connect the cable from the positive (red) terminal of the PROwatt 600 to the positive terminal of the battery.

This is the last cable connection. A spark is normal when you make it.

9.If you have installed a battery selector switch, use it to select one of the batteries.

10.Turn on the inverter’s On/Off switch.

11.Check the inverter’s front panel. The POWER indicator should be on. If it is not, or if the FAULT indicator is on, check your battery and the connections to the inverter.

14