Configuration
975-0170-01-01 3–21
Lo DC Volt
Full name Low DC input voltage shutdown
Configurable setting This setting lets you set the low voltage shutdown level for the inverter.
You can adjust the Lo DC Volt settings as follows:
When to use This setting limits the depth of discharge on your battery.
Batt Type
This feature is the same as described on the basic menu on page 3–16.
Batt Size
This feature is the same as described on the basic menu on page 3–17.
Sense Below
Configurable setting This setting lets you adjust the load power at which the inverter will turn
on. This setting saves battery consumption by keeping the inverter
disabled (turned off) except when load demand is present.
You can adjust the Sense Below settings as follows:
When to use Adjust this setting to control the inverter based on the load.
Outcome Sets the load threshold at a power level where you want the inverter to
stay on, for example, when a sufficient load is applied. For more
information on this feature, see “Load Sense Mode” on page2–6.
Lo DC Volt [10.0V]
Range Increment Default
10 to 12 volts 0.1 volt 10 volts
Sense Below [50W]
Range of values Increment Default
40 watts to 150 watts 10 watts 50 watts