8.0 Output Protection Fuse Replacement
The Truecharge has two
1.Disconnect AC power to the Truecharge and disconnect the DC cables at the battery(s).
2.Remove the wiring compartment cover by removing the 4 screws that attach it to the Truecharge.
3.Locate the fuses just inside the upper left corner of the wiring compartment.
4.Pull each fuse directly toward the Truecharge’s mounting surface to remove them from their fuseholders. Never pull towards the lower end of the unit, or wiggle the fuses back and forth to remove them.
5.Replace any blown fuse with an identical 15 amp, 32 volt rated, automotive
6.Find and correct the problem that caused the fuse(s) to blow. Generally this will be reversed battery polarity.
7.Replace the wiring compartment cover and reconnect AC and DC power.
17