![](/images/backgrounds/272835/272835-2622x1.png)
Truecharge 10TB Owner’s Manual
Problem: "Bulk" light (only) flashes (the Truecharge is detecting excessive internal temperature).
Possible Cause
The Truecharge has shut down due to internal overheating.
Suggested Remedy
Eliminate ventilation blockage or reduce ambient temperature to less than 105°F (40°C). The Truecharge will resume normal operation once it has cooled sufficiently.
Problem: Long charging times. "Ready/Float" light does not switch on even after 24 hours of charging.
Possible Cause
Total battery capacity is higher than the recommended 200
Load connected to battery is continuously operating, thus diverting the charge current directly to the load.
Battery has damaged cell.
Suggested Remedy
Total battery capacity (the sum of both
This is a normal situation if a load is drawing current from the battery. Once the load is switched off, normal charging will resume.
Replace battery.
19