Truecharge 10TB Owner’s Manual

Problem: "Bulk" light (only) flashes (the Truecharge is detecting excessive internal temperature).

Possible Cause

The Truecharge has shut down due to internal overheating.

Suggested Remedy

Eliminate ventilation blockage or reduce ambient temperature to less than 105°F (40°C). The Truecharge will resume normal operation once it has cooled sufficiently.

Problem: Long charging times. "Ready/Float" light does not switch on even after 24 hours of charging.

Possible Cause

Total battery capacity is higher than the recommended 200 Ampere-Hours.

Load connected to battery is continuously operating, thus diverting the charge current directly to the load.

Battery has damaged cell.

Suggested Remedy

Total battery capacity (the sum of both Ampere-Hour ratings if two batteries are installed) must be 200 Ampere- hours or less, or excessive charging times will result.

This is a normal situation if a load is drawing current from the battery. Once the load is switched off, normal charging will resume.

Replace battery.

19