Xerox 4890 IPS manual Replacing the pressure roll wiper

Models: 4890 IPS

1 68
Download 68 pages 32.46 Kb
Page 26
Image 26

FUSER LUBRICANT AND PRESSURE ROLL WIPER

11.Remove and dispose of the gloves in a trash receptacle, being careful not to let any residue come in contact with your skin.

12.Close the printer doors.

13.Wash your hands to remove any fuser lubricant.

Replacing the pressure roll wiper

You need to replace the pressure roll wiper when any of the following occur:

Excessive oil or dirt buildup appears on the wiper.

The first few prints of a job have oil or dirt on them.

An interval of 80,000 to 100,000 prints are made. (The number of prints made is tracked by the billing meter, which you can view through the Administration pull-down menu on the IPS main window.)

Your service representative usually replaces the pressure roll wiper for the DocuPrint System. However, you might choose to replace the pressure roll wiper yourself if you have been previously trained in this procedure.

To replace the wiper:

1.Power off the printer.

2.Open the printer doors and locate the fuser drawer.

3.Move the green lever (A) counter-clockwise, grasp the green handle on the fuser drawer, (B) and pull it out until it stops.

A

B

4-4

XEROX DOCUPRINT 4850/4890 IPS GUIDE TO PERFORMING ROUTINE MAINTENANCE

Page 26
Image 26
Xerox 4890 IPS manual Replacing the pressure roll wiper