99Add-9
Type 30:Early Ref Vocal ~ 35:Early Ref Reverse Vocal
(Early Reflection Type)
No. Parameter Name Unit Minimum Maximum Step/Table Max.Int. Local
Table 1
1 Type sec S-Hall Spring LocalTab
15 Data Value
2 Room Size - 0.1 20.0 0.1 199
3 Liveness - 0 10 1 10 0 S-Hall
4 Diffusion - 0 10 1 10 1 L-Hall
5 Initial Delay ms 0.1 400.0 0.1 3999 2 Random
6 ER Number - 1 19 1 18 3 Reverse
7 Feedback Delay ms 0.1 800.0 0.1 7999 4 Plate
8 Feedback Gain % -99 99 1 198 5 Spring
9 HPF Hz Thru 1000 Table #3 31
10 LPF KHz 1 Thru Table #2 25
Type 36:Gate Reverb ~ 37:Reverse Gate
No. Parameter Name Unit Minimum Maximum Step/Table Max.Int. Local
Table 1
1 Type sec Type-A Type-B LocalTab
11 Data Value
2 Room Size - 0.1 20.0 0.1 199
3 Liveness - 0 10 1 10 0 Type-A
4 Diffusion - 0 10 1 10 1 Type-B
5 Initial Delay ms 0.1 400.0 0.1 3999
6 ER Number - 1 19 1 18
7 Feedback Delay ms 0.1 800.0 0.1 7999
8 Feedback Gain % -99 99 1 198
9 HPF Hz Thru 1000 Table #3 31
10 LPF KHz 1 Thru Table #2 25
Type 38:Delay L,R
No. Parameter Name Unit Minimum Maximum Step/Table Max.Int.
1 Lch Delay Time ms 0.1 1360.0 0.1 13599
2 Rch Delay Time ms 0.1 1360.0 0.1 13599
3
4 FB1 Delay Time ms 0.1 1360.0 0.1 13599
5 FB2 Delay Time ms 0.1 1360.0 0.1 13599
6 FB Gain % -99 99 1 198
7 FB1 High Control - 0.1 1.0 0.1 9
8 FB2 High Control - 0.1 1.0 0.1 9
9 HPF Hz Thru 1000 Table #3 31
10 LPF KHz 1 Thru Table #2 25