RECORDING FROM AN EXTERNAL COMPONENT ONTO THE HDD

Setting a condition for synchronized recording

This unit automatically detects track intervals when recording is made in track-synchronized recording mode, multi-synchronized recording mode, or all-synchronized recording mode. You can set the condition for detecting track intervals. Setting items are as follows.

 

MULTI JOG

MENU

ER

 

MULTI JOG

 

 

PUSH ENTER

 

 

TEXT/TIME

MODE

MENU

 

TRACK NO.

COMPLETE

CLEAR

 

BOOKMARK

 

 

 

 

DIGITAL REC LEVEL

 

COPY

 

 

 

 

 

INPUT ANALOG REC LEVEL

 

REC FINALIZE ERASE OPTICAL

 

A.M.Q.R.

 

COAXIAL

 

 

 

ANALOG

 

 

 

MIN

MAX

0

10

 

 

MODE

MENU

 

 

 

 

MENU

 

H, G

ENTER

ENTER

 

COMPLETE

CLEAR

 

 

TRACK NO.

WRITE

HDD

+, –

CDR

1. Press MENU while this unit is in the stop mode.

Menu item selection appears on the display.

2. Rotate the MULTI JOG knob (press +/–, H or G on the remote control) to select “Synchro Setup”.

S y n c h r o S e t u p

L

dB –30 –10 –6 –2 0

R

3. Press the MULTI JOG knob (ENTER on the remote control).

Setting item selection appears on the display.

4. Rotate the MULTI JOG knob (press +/–, H or G on the remote control) to select a setting item.

OPT TH Level

Sets the signal level that judges the signals input through the DIGITAL IN (OPTICAL) jack as “no signal”.

Initial setting: –50dB, Control range: –90 to –20dB

COAX TH Level

Sets the signal level that judges the signals input through the DIGITAL IN (COAXIAL) jack as “no signal”.

Initial setting: –50dB, Control range: –90 to –20dB

ANLG TH Level

Sets the signal level that judges the signals input through the ANALOG LINE IN (REC) jacks as “no signal”.

Initial setting: –40dB, Control range: –60 to –20dB

Int. Time

Sets the length of silence (“no signal”) that judges track intervals. When the set amount of silence continues, this unit judges it as a track interval and places a track marker.

Initial setting: 2.0 seconds, Control range: 0.5 to 5.0 seconds

End Duration

Sets the length of silence (“no signal”) that judges the end of playback when recording in the all-synchronized recording mode. When the set amount of silence continues, recording will be stopped.

Initial setting: 12.0 seconds, Control range: 2.0 to 60.0 seconds

Memo

If you set a TH (threshold) level, a signal less than the specified TH level is not input through the jack (considered as “no signal”).

Settings for “Int. Time” and “End Duration” apply to each input jack.

5. Press the MULTI JOG knob (ENTER on the remote control) to confirm the setting item.

If “OPT TH Level”, “COAX TH Level” or “ANLG TH Level” is confirmed, follow the “When OPT TH Level, COAX TH Level, or ANLG TH Level is selected” procedure below.

If “Int. Time” or “End Duration” is confirmed, follow the “When Int. Time or End Duration is selected” procedure below.

(When OPT TH Level, COAX TH Level, or ANLG TH Level is selected)

6. Rotate the MULTI JOG knob (press +/–, H or G on the remote control) to adjust the level.

Level can be set by 1dB step.

Example: To set “ANLG TH Level”

A N L G T H - 4 0 d B LEVEL

L

dB –30 –10 –6 –2 0

R

7. Press the MULTI JOG knob (ENTER on the remote control) to confirm the level.

Setting item selection appears on the display.

(When Int. Time or End Duration is selected)

6. Rotate the MULTI JOG knob (+/–, H or G on the remote control) to set an interval.

“Int. Time” can be set by 0.5-second steps, and “End Duration” can be set by 1.0-second steps.

Example: To set “Int.Time”

T i m e

2 . 0 s e c

 

 

L

 

 

 

dB –30 –10 –6 –2

0

TIME

 

R

 

 

 

 

 

7. Press the MULTI JOG knob (ENTER on the remote control) to set an interval.

Setting item selection appears on the display.

Press MENU twice to close the menu and return to the normal stop mode.

36