Monitor and Cue
V1.7 Supplementary Manual
10
Monitor and Cue

Extended cue functions

The cue monitor level range has been expanded to –30 dB – +20 dB.
Make this setting in the CUE popup window.
Accessing the CUE popup window
1. In the Function Access Area, press the MONITOR button to access the MONITOR
screen.
2. Press the CUE popup display button.
Use the knob to adjust the monitor level in the range of –30 dB – +20 dB.
Meters

Added functions for meter display

PRE GC METER and POST DIGITAL GAIN METER have been added to the METERING POINT
field of the METER screen. In addition, the name of PRE HPF has been changed to PRE D.GAIN.
Select the meter point at which the level will be detected.
For INPUT METER
PRE GC....................................... Immediately before GAIN COMPENSATION
POST D.GAIN...........................Immediately after DIGITAL GAIN