Monitor and Cue
V1.7 Supplementary Manual
10
Monitor and CueExtended cue functions
The cue monitor level range has been expanded to –30 dB – +20 dB.
Make this setting in the CUE popup window.
■Accessing the CUE popup window
1. In the Function Access Area, press the MONITOR button to access the MONITOR
screen.
2. Press the CUE popup display button.
Use the knob to adjust the monitor level in the range of –30 dB – +20 dB.
MetersAdded functions for meter display
PRE GC METER and POST DIGITAL GAIN METER have been added to the METERING POINT
field of the METER screen. In addition, the name of PRE HPF has been changed to PRE D.GAIN.
Select the meter point at which the level will be detected.
■For INPUT METER
•PRE GC....................................... Immediately before GAIN COMPENSATION
•POST D.GAIN...........................Immediately after DIGITAL GAIN