46

(5) XG Native Bulk Data (reception only)

Data format: [F0H] -> [43H] -> [0nH] -> [4CH] -> [aa] ->

[bb] -> [hh] -> [mm] -> [ll] -> [dd] ->...-> [cc]

-> [F7H]

F0 Exclusive status
43 YAMAHA ID
0n When n is received n=0~F, whichever is received.
When n is transmitted n always=0.
4C Model ID of XG
aa ByteCount
bb ByteCount
hh Address High
mm Address Mid
ll Address Low
dd Data
| |
| |
cc Check sum
F7 End of Exclusive
For information about “Address” and “Byte Count” fields, refer to
attached tables.
In the attached tables “TOTAL SIZE” partitions a data series into
single bulk dumps. The “address” is the first byte of the bulk data.
The checksum value is set such that the sum of Byte Count, Ad-
dress, Data, and Checksum has value zero in its seven least
significant bits.
If too much bulk data is received at a time there is a chance of
error. The total data for a bulk dump should not exceed 512 bytes,
it is recommended that data be kept under 512 bytes with an
interval time of 120msec or more between 512 byte bulk.

(6) Clavinova MIDI Format

Data format: [F0H] -> [43H] -> [73H] -> [3BH] -> [yy] ->

[F7H]
F0 = Exclusive status
43H = Yamaha ID
73H = Clavinova ID
3BH = CLP-411/511 ID
yy = Substatus
yy Information
02H Internal MIDI clock
03H External MIDI clock
06H Bulk Data
* The bulk data follows 06H.
* When yy=2, 3 or Clavinova common ID (01H) is recog-
nized
as well as 3BH.
BULK DUMP FORMAT
F0H, 43H, 73H
nnH (Product ID: CLP-411=42H,
CLP-511=43H)
06H (Bulk ID)
05H (Sequence data, Bulk Dump Format)
0xH, 0xH, 0xH, 0xH (Data length= xxxx bytes)
[BULK DATA] (low, high........low, high)
[CHECK SUM (1byte)] = 0-sum (BULK DATA)
F7H

(7) Special Control

Data format: [F0H] -> [43H] -> [73H] -> [3BH] -> [11H] ->

[0nH] -> [cc] -> [vv] -> [F7H]

43H = Yamaha ID
73H = Clavinova ID
3BH = CLP-411/511 ID
11H = Clavinova special control
0nH = Control MIDI change + channel number
cc = Control number
vv = Value
Control 0nH ccH dd
Split Point Always 00 14H 14H :
Split Key Number
(CLP-511)
Metronome Always 00 1BH 00H : off
01H : –
02H : 2/4
03H : 3/4
04H : 4/4
05H : 5/4
06H : 6/4
07H : No accent
Channel Detune ch: 00-0F 43H 00H-7FH
Voice Reserve ch: 00-0F 45H 00H : Reserve off
7FH : on
*1 When Volume, Expression is received for Reserve On, they will be
effective from the next Key On. Reserve Off is normal.

(8) Others

Data format: [F0H] -> [43H] -> [1nH] -> [27H] -> [30H] ->

[00H] -> [00H] -> [mmH] -> [llH] -> [ccH] -> [F7H]

Master Tuning (XG and last message priority) simultaneously changes the
pitch of all channels.
F0H = Exclusive Status
43H = Yamaha ID
1nH = Transmission from n=CLP is always 0. 0-F is received.
27H = Model ID of TG100
30H = Sub ID
00H =
00H =
mmH = Master Tune MSB
llH = Master Tune LSB
ccH = don’t care (under 7FH)
F7H = End of Exclusive
MIDI Data Format/MIDI-Datenformat/Format des données MIDI/Formato de datos MIDI

<Table 1-1>

MIDI Parameter Change table ( SYSTEM )

Address (H) Size (H) Data (H) Parameter Description Default value (H)
00 00 00 4
020C - 05F4(*1)
MASTER TUNE -50 - +50[cent] 00 04 00 00
01 1st bit 3 - 0 bit 15 - 12 400
02 2nd bit 3 - 0 bit 11 - 8
03 3rd bit 3 - 0 bit 7 - 4
4th bit 3 - 0 bit 3 - 0
04 1 00 - 7F MASTER VOLUME 0 - 127 7F
05 1
06 1 34 - 4C(*2) TRANSPOSE -12 - +12[semitones] 40
7E 00 XG SYSTEM ON 00=XG sytem ON
7F 00 RESET ALL PARAMETERS 00=ON (receive only)
TOTAL SIZE 07
*1: Values lower than 020CH select -50 cents. Values higher than 05F4H select +50 cents.
*2: Values from 28 through 33 are interpreted as -12 through -1. Values from 4D through 58 are interpreted as +1 through +12.

<Table 1-2>

MIDI Parameter Change table ( EFFECT 1)

Refer to the “Effect MIDI Map” for a complete list of Reverb, Chorus and Variation type numbers.
Address (H) Size (H) Data (H) Parameter Description Default value (H)
02 01 00 2 00-7F REVERB TYPE MSB Refer to Effect MIDI Map 01(=HALL1)
00-7F REVERB TYPE LSB 00 : basic type 00
0C 1 00-7F REVERB RETURN -dB...0dB...+6dB(0...64...127) 40
TOTAL SIZE 0E
02 01 40 2 00-7F VARIATION TYPE MSB Refer to Effect MIDI Map 00(=Effect off)
00-7F VARIATION TYPE LSB 00 : basic type 00
TOTAL SIZE 21
* “VARIATION” refers to the EFFECT on the panel.