1 Set up the CRW-F1SX Drive

1 Set up the CRW-F1SX Drive

Prior to connecting the CRW-F1SX drive to the computer, set up the following using the dip switch of the drive.

SCSI ID Number

Termination

 

Dip switch 124

 

 

IDTERMINATORSELECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCSI ID Number

Each of the SCSI devices connected to the computer needs to be identified by its own SCSI ID number from “0” to “7.” The SCSI ID number “7” is normally reserved for the SCSI card. Therefore, assigning a SCSI ID number from “0” to “6,” except for the ID numbers in use by other SCSI devices, to the CRW-F1SX drive is recommended.

The dip switch of the CRW-F1SX has four switches, and use SW 1, SW 2, and SW 3 (three switches from the left) to set the SCSI ID number. The switches are set to ON when pulled down. Each switch set to ON counts each ID SELECT number, and the sum total of the ID SELECT number determines SCSI ID number as the SCSI ID table shown on page 13.

Continued on next page