Specifications■General Specifications
Output impedance of signal generator: 150 ohms
* These specifications apply to rated power supplies of 120V, 230V and 240V.
MIN TYP MAX UNIT
Maximum Output Power
(SPEAKERS)
(RL=4 ohms) Both ch drive, 1kHz, THD+N 0.5% 500
W
(RL=8 ohms) 350
(US,AU)
320
(EU)
Total Harmonic Distortion
(THD+N) 20 Hz-20 kHz
(ST, ST SUB, AUX, EFFECT)+14dBu output into 600 ohms 0.3 %
(REC) 0 dBV output into 10 kohms 0.5 %
Frequency Response (ST, ST SUB, AUX, EFFECT) GAIN at minimum level, PAD=OFF, 20Hz-20kHz,
nominal output level @ 1kHz
–3.0 0.0 1.0 dB
(SPEAKERS) –3.0 0.0 1.0 dB
EIN=Equivalent Input Noise (ST OUT) GAIN at maximum level, 20Hz-20kHz –128 dBu
Residual Output Noise (SPEAKERS) –68 dBu
(ST, ST SUB, AUX) –95 dBu
Crosstalk @ 1kHz adjacent inputs –68 dB
input to output –68 dB
Maximum Voltage Gain
@1kHz
CH MIC INPUT → SPEAKERS 109 dB
CH MIC INPUT → ST OUT 84 dB
CH MIC INPUT → AUX SEND (PRE), ST SUB 80 dB
CH MIC INPUT → AUX SEND (POST) 90 dB
CH MIC INPUT → EFFECT SEND 78 dB
CH MIC INPUT → REC OUT 62.2 dB
ST CH 11/12,13/14 → ST OUT 58 dB
Phantom Voltage (CHs 1-6, 7/8, 9/10) No load 48 V DC
Monaural/Stereo channel
Equalizer
± 15 dB (Maximum Variation)
Turn over/roll-off frequency of shelv-
ing, 3 dB below maximum variable
level.
HIGH 10kHz (shelving)
MID (MONO) 250-5kHz (peaking)
MID (ST) 2.5kHz (peaking)
LOW 100Hz (shelving)
PEAK Indicator On each channel: indicator lights if post-EQ signal (on ST channels, if either
post-EQ signal or post-mic-amp signal) comes within 3 dB of the clipping level.
SIGNAL Indicator On each channel: indicator lights if post-EQ signal (on ST channels, if either
post-EQ signal or post-mic-amp signal) reaches –10 dB.
FCL Indicator Input signal level: –75dB
LEVEL meter (ST, PFL/AFL) Two 12-points LED level meter (PEAK, +5, +3, +1,0, –1, –3, –5, –7, –10, –15,
–20 dB)
PEAK lights if the signal comes within 3 dB of the clipping level.
Graphic Equalizer (ST OUT)9 band (63, 125, 250, 500, 1k, 2k, 4k, 8k, 16 kHz) ±12 dB (Maximum Variation)
Internal Digital Effect 16 programs, Parameter control
Foot Switch (Internal Effect ON/OFF)
Power Amplifier Protection POWER Switch on/off mute
DC-fault: power supply shutdown/manual reset
Thermal/heatsink temp 90˚C: output mute/auto reset
Vl limiter /RL 2 ohms
Clip limiter/THD 1 % , Indicator × 2
Power Supply Protection Thermal/heatsink temp 100˚C: power supply shutdown/manual reset
Cooling Dual variable-speed fan
<
=
>
=
<
=
>
=
>
=
MIN TYP MAX UNIT
Power Consumption 500 W
AC Cord Length 2500 mm
Dimensions Height 155 mm
Depth 493 mm
Width 444 mm
Weight 10.5 kg